A unified Bayesian hierarchical model for MRI tissue classification. (28th October 2013)
- Record Type:
- Journal Article
- Title:
- A unified Bayesian hierarchical model for MRI tissue classification. (28th October 2013)
- Main Title:
- A unified Bayesian hierarchical model for MRI tissue classification
- Authors:
- Feng, Dai
Liang, Dong
Tierney, Luke - Abstract:
- <abstract abstract-type="main" id="sim6018-abs-0001"> <title>Abstract</title> <p>Various works have used magnetic resonance imaging (MRI) tissue classification extensively to study a number of neurological and psychiatric disorders. Various noise characteristics and other artifacts make this classification a challenging task. Instead of splitting the procedure into different steps, we extend a previous work to develop a unified Bayesian hierarchical model, which addresses both the partial volume effect and intensity non‐uniformity, the two major acquisition artifacts, simultaneously. We adopted a normal mixture model with the means and variances depending on the tissue types of voxels to model the observed intensity values. We modeled the relationship among the components of the index vector of tissue types by a hidden Markov model, which captures the spatial similarity of voxels. Furthermore, we addressed the partial volume effect by construction of a higher resolution image in which each voxel is divided into subvoxels. Finally, We achieved the bias field correction by using a Gaussian Markov random field model with a band precision matrix designed in light of image filtering. Sparse matrix methods and parallel computations based on conditional independence are exploited to improve the speed of the Markov chain Monte Carlo simulation. The unified model provides more accurate tissue classification results for both simulated and real data sets. Copyright © 2013 John Wiley<abstract abstract-type="main" id="sim6018-abs-0001"> <title>Abstract</title> <p>Various works have used magnetic resonance imaging (MRI) tissue classification extensively to study a number of neurological and psychiatric disorders. Various noise characteristics and other artifacts make this classification a challenging task. Instead of splitting the procedure into different steps, we extend a previous work to develop a unified Bayesian hierarchical model, which addresses both the partial volume effect and intensity non‐uniformity, the two major acquisition artifacts, simultaneously. We adopted a normal mixture model with the means and variances depending on the tissue types of voxels to model the observed intensity values. We modeled the relationship among the components of the index vector of tissue types by a hidden Markov model, which captures the spatial similarity of voxels. Furthermore, we addressed the partial volume effect by construction of a higher resolution image in which each voxel is divided into subvoxels. Finally, We achieved the bias field correction by using a Gaussian Markov random field model with a band precision matrix designed in light of image filtering. Sparse matrix methods and parallel computations based on conditional independence are exploited to improve the speed of the Markov chain Monte Carlo simulation. The unified model provides more accurate tissue classification results for both simulated and real data sets. Copyright © 2013 John Wiley &amp; Sons, Ltd.</p> </abstract> … (more)
- Is Part Of:
- Statistics in medicine. Volume 33:Number 8(2014)
- Journal:
- Statistics in medicine
- Issue:
- Volume 33:Number 8(2014)
- Issue Display:
- Volume 33, Issue 8 (2014)
- Year:
- 2014
- Volume:
- 33
- Issue:
- 8
- Issue Sort Value:
- 2014-0033-0008-0000
- Page Start:
- 1349
- Page End:
- 1368
- Publication Date:
- 2013-10-28
- Subjects:
- Medical statistics -- Periodicals
Statistique médicale -- Périodiques
Statistiques médicales -- Périodiques
610.727 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/sim.6018 ↗
- Languages:
- English
- ISSNs:
- 0277-6715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8453.576000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3189.xml