Validation of patient specific surgical guides in total hip arthroplasty. Issue 1 (31st October 2013)
- Record Type:
- Journal Article
- Title:
- Validation of patient specific surgical guides in total hip arthroplasty. Issue 1 (31st October 2013)
- Main Title:
- Validation of patient specific surgical guides in total hip arthroplasty
- Authors:
- Sakai, Takashi
Hanada, Toshihisa
Murase, Tsuyoshi
Kitada, Makoto
Hamada, Hidetoshi
Yoshikawa, Hideki
Sugano, Nobuhiko - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="rcs1547-sec-0001" sec-type="section"> <title>Background</title> <p>The validation of patient‐specific surgical guides (PSGs) by their design and the comparison of planned and actual PSG setting in total hip arthroplasty (THA) have not previously been reported.</p> </sec> <sec id="rcs1547-sec-0002" sec-type="section"> <title>Methods</title> <p>The errors between preoperative planning and computed tomography (CT)‐based PSG setting (E1), and between preoperative planning and implantation (E2) were evaluated using CT in 16 fresh cadaveric hips.</p> </sec> <sec id="rcs1547-sec-0003" sec-type="section"> <title>Results</title> <p>E2 was significantly smaller with the wide‐base‐contact resurfacing‐THA PSG than with the narrow‐base‐contact type (<italic>P</italic> &lt; 0.05). E1/E2 of the wide‐base‐contact neck‐cut PSG was 1.6 ± 0.7°/2.4 ± 1.1° for the coronal plane and 1.2 ± 0.8 mm/0.7 ± 0.5 mm for the medial neck‐cut height. E1/E2 of the wide‐base‐contact cup‐impaction PSG was 1.0 ± 0.9°/3.4 ± 1.9° for inclination and 1.7 ± 1.1°/6.6 ± 4.4° for anteversion.</p> </sec> <sec id="rcs1547-sec-0004" sec-type="section"> <title>Conclusions</title> <p>The wide‐base‐contact PSG in resurfacing‐THA and the PSG for neck‐cut in THA could be applied clinically. Although cup‐impaction PSG setting was acceptable, errors were made due to the impaction process during cup implantation. Copyright © 2013 John Wiley &amp; Sons, Ltd.</p><abstract abstract-type="main"> <title>Abstract</title> <sec id="rcs1547-sec-0001" sec-type="section"> <title>Background</title> <p>The validation of patient‐specific surgical guides (PSGs) by their design and the comparison of planned and actual PSG setting in total hip arthroplasty (THA) have not previously been reported.</p> </sec> <sec id="rcs1547-sec-0002" sec-type="section"> <title>Methods</title> <p>The errors between preoperative planning and computed tomography (CT)‐based PSG setting (E1), and between preoperative planning and implantation (E2) were evaluated using CT in 16 fresh cadaveric hips.</p> </sec> <sec id="rcs1547-sec-0003" sec-type="section"> <title>Results</title> <p>E2 was significantly smaller with the wide‐base‐contact resurfacing‐THA PSG than with the narrow‐base‐contact type (<italic>P</italic> &lt; 0.05). E1/E2 of the wide‐base‐contact neck‐cut PSG was 1.6 ± 0.7°/2.4 ± 1.1° for the coronal plane and 1.2 ± 0.8 mm/0.7 ± 0.5 mm for the medial neck‐cut height. E1/E2 of the wide‐base‐contact cup‐impaction PSG was 1.0 ± 0.9°/3.4 ± 1.9° for inclination and 1.7 ± 1.1°/6.6 ± 4.4° for anteversion.</p> </sec> <sec id="rcs1547-sec-0004" sec-type="section"> <title>Conclusions</title> <p>The wide‐base‐contact PSG in resurfacing‐THA and the PSG for neck‐cut in THA could be applied clinically. Although cup‐impaction PSG setting was acceptable, errors were made due to the impaction process during cup implantation. Copyright © 2013 John Wiley &amp; Sons, Ltd.</p> </sec> </abstract> … (more)
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 10:Issue 1(2014)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 10:Issue 1(2014)
- Issue Display:
- Volume 10, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2014-0010-0001-0000
- Page Start:
- 113
- Page End:
- 120
- Publication Date:
- 2013-10-31
- Subjects:
- Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.1547 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4042.xml