Fast magnetization transfer and apparent T1 imaging using a short saturation pulse with and without inversion preparation. Issue 3 (19th April 2013)
- Record Type:
- Journal Article
- Title:
- Fast magnetization transfer and apparent T1 imaging using a short saturation pulse with and without inversion preparation. Issue 3 (19th April 2013)
- Main Title:
- Fast magnetization transfer and apparent T1 imaging using a short saturation pulse with and without inversion preparation
- Authors:
- Kim, Tae
Shin, Wanyong
Kim, Seong‐Gi - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm24756-sec-0001" sec-type="section"> <title>Purpose</title> <p>Measurements of magnetization transfer (MT) metrics, such as the steady‐state (SS) MT ratio and apparent longitudinal relaxation rate require multiple MT irradiation durations and a long experimental time. To overcome these problems, we propose a novel method using a short MT off‐resonance pulse with and without on‐resonance inversion preparation pulse.</p> </sec> <sec id="mrm24756-sec-0002" sec-type="section"> <title>Theory and Methods</title> <p>Computer simulations were performed to examine the accuracy of the proposed method and to find the optimal off‐resonance irradiation pulse duration (<italic>T</italic><sub>irad</sub>) and power level (<italic>ω</italic><sub>1</sub>). Our approach, with echo planar imaging data acquisition, was applied to animals at 9.4 T and humans at 3 T with <italic>ω</italic><sub>1</sub>/2π = 100 Hz and 177 Hz, respectively. Steady‐state MT ratio and relaxation rate were obtained from a pair of MT images at a <italic>T</italic><sub>irad</sub>, with and without inversion.</p> </sec> <sec id="mrm24756-sec-0003" sec-type="section"> <title>Results</title> <p>For <italic>T</italic><sub>irad</sub> ≥ 0.4 s, steady‐state MT ratio, and relaxation rate measured at any single <italic>T</italic><sub>irad</sub> agreed well with those of the conventional fitting method that uses multiple<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm24756-sec-0001" sec-type="section"> <title>Purpose</title> <p>Measurements of magnetization transfer (MT) metrics, such as the steady‐state (SS) MT ratio and apparent longitudinal relaxation rate require multiple MT irradiation durations and a long experimental time. To overcome these problems, we propose a novel method using a short MT off‐resonance pulse with and without on‐resonance inversion preparation pulse.</p> </sec> <sec id="mrm24756-sec-0002" sec-type="section"> <title>Theory and Methods</title> <p>Computer simulations were performed to examine the accuracy of the proposed method and to find the optimal off‐resonance irradiation pulse duration (<italic>T</italic><sub>irad</sub>) and power level (<italic>ω</italic><sub>1</sub>). Our approach, with echo planar imaging data acquisition, was applied to animals at 9.4 T and humans at 3 T with <italic>ω</italic><sub>1</sub>/2π = 100 Hz and 177 Hz, respectively. Steady‐state MT ratio and relaxation rate were obtained from a pair of MT images at a <italic>T</italic><sub>irad</sub>, with and without inversion.</p> </sec> <sec id="mrm24756-sec-0003" sec-type="section"> <title>Results</title> <p>For <italic>T</italic><sub>irad</sub> ≥ 0.4 s, steady‐state MT ratio, and relaxation rate measured at any single <italic>T</italic><sub>irad</sub> agreed well with those of the conventional fitting method that uses multiple <italic>T</italic><sub>irad</sub>. Our simulation indicates that a higher <italic>ω</italic><sub>1</sub> can use a shorter Tirad.</p> </sec> <sec id="mrm24756-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Steady‐state MT ratio and relaxation rate can be determined from MT data with only one, short <italic>T</italic><sub>irad</sub> by incorporation of an inversion prepulse. This MT imaging approach is simple, fast, and easily implementable. <bold>Magn Reson Med 71:1264–1271, 2014. © 2013 Wiley Periodicals, Inc</bold>.</p> </sec> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 71:Issue 3(2014:Mar.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 71:Issue 3(2014:Mar.)
- Issue Display:
- Volume 71, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 71
- Issue:
- 3
- Issue Sort Value:
- 2014-0071-0003-0000
- Page Start:
- 1264
- Page End:
- 1271
- Publication Date:
- 2013-04-19
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24756 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3868.xml