Versatile online SPE–HPLC method for the analysis of Irinotecan and its clinically relevant metabolites in biomaterials. Issue 4 (10th January 2014)
- Record Type:
- Journal Article
- Title:
- Versatile online SPE–HPLC method for the analysis of Irinotecan and its clinically relevant metabolites in biomaterials. Issue 4 (10th January 2014)
- Main Title:
- Versatile online SPE–HPLC method for the analysis of Irinotecan and its clinically relevant metabolites in biomaterials
- Authors:
- Prijovich, Zeljko M.
Burnouf, Pierre‐Alain
Roffler, Steve R. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Monitoring levels of Irinotecan and its metabolites during cancer therapy could help link broad interpatient variations in antitumor activity and toxicity to the patient's metabolic status. We have developed and validated a versatile and highly sensitive method for the simultaneous determination of Irinotecan and its clinically relevant metabolites 7‐ethyl‐10‐hydroxy‐camptothecin (SN‐38) and SN‐38 glucuronide. Sample clean‐up involves precipitation by acetone/methanol/0.5 M trichloroacetic acid at 4:4:2 v/v followed by extraction of the metabolites on an SPE column by 20% methanol in 25 mM KH<sub>2</sub>PO<sub>4</sub> pH 2.9. Online transfer to an analytical μBondapak C18 column, elution with 24% acetonitrile (ACN) in 0.1 M KH<sub>2</sub>PO<sub>4</sub> pH 2.9 and fluorescence detection with excitation at 375 nm and emission at 430 nm for SN‐38 glucuronide and Irinotecan or 540 nm for SN‐38 results in high sensitivity (1–2 pg) and short (∼10 min) run times. The method was used to determine the degree of SN‐38 glucuronidation in mice after Irinotecan administration and in cultured cancer cells exposed to SN‐38. The method may be used to better understand Irinotecan metabolism, personalize therapy, and develop Irinotecan‐based tumor targeting therapies.</p> </abstract>
- Is Part Of:
- Journal of separation science. Volume 37:Issue 4(2014:Feb.)
- Journal:
- Journal of separation science
- Issue:
- Volume 37:Issue 4(2014:Feb.)
- Issue Display:
- Volume 37, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 37
- Issue:
- 4
- Issue Sort Value:
- 2014-0037-0004-0000
- Page Start:
- 360
- Page End:
- 367
- Publication Date:
- 2014-01-10
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201301191 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4259.xml