Improving outcomes of screening breast MRI with practice evolution: Initial clinical experience with 3T compared to 1.5T. Issue 3 (29th May 2013)
- Record Type:
- Journal Article
- Title:
- Improving outcomes of screening breast MRI with practice evolution: Initial clinical experience with 3T compared to 1.5T. Issue 3 (29th May 2013)
- Main Title:
- Improving outcomes of screening breast MRI with practice evolution: Initial clinical experience with 3T compared to 1.5T
- Authors:
- Lourenco, Ana P.
Donegan, Linda
Khalil, Hanan
Mainiero, Martha B. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24198-sec-0001" sec-type="section"> <title>Purpose</title> <p>To determine if changing from 1.5T to 3T breast magnetic resonance imaging (MRI) is associated with a change in BI‐RADS categories, positive predictive value of biopsy recommendation, or cancer detection rates in high‐risk screening breast MRI.</p> </sec> <sec id="jmri24198-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Institutional Review Board (IRB) approval was obtained for this Health Insurance Portability and Accountability Act (HIPAA)‐compatible retrospective review. Prior to October 2010, breast MRI was performed at 1.5T and after October 2010 breast MRI was performed at 3T. Reports of 495 consecutive screening 3T breast MRI exams from October 2010 through October 2011 were reviewed. Comparison was made to previously collected data on 650 screening breast MRI exams at 1.5T. Data were analyzed for statistical significance using the two‐sample test of proportions.</p> </sec> <sec id="jmri24198-sec-0003" sec-type="section"> <title>Results</title> <p>There were 495 screening breast MRI exams. There were 419 (84.6%) BI‐RADS 1/2 results, 35 (7.1%) BI‐RADS 3 results, and 41 (8.3%) BI‐RADS 4/5 results. BI‐RADS 4/5 results increased at 3T (<italic>P</italic> = 0.04). The positive predictive value for BI‐RADS 4/5 was 29.3% (12/41) at 3T, compared with 17.6% at 1.5T<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24198-sec-0001" sec-type="section"> <title>Purpose</title> <p>To determine if changing from 1.5T to 3T breast magnetic resonance imaging (MRI) is associated with a change in BI‐RADS categories, positive predictive value of biopsy recommendation, or cancer detection rates in high‐risk screening breast MRI.</p> </sec> <sec id="jmri24198-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Institutional Review Board (IRB) approval was obtained for this Health Insurance Portability and Accountability Act (HIPAA)‐compatible retrospective review. Prior to October 2010, breast MRI was performed at 1.5T and after October 2010 breast MRI was performed at 3T. Reports of 495 consecutive screening 3T breast MRI exams from October 2010 through October 2011 were reviewed. Comparison was made to previously collected data on 650 screening breast MRI exams at 1.5T. Data were analyzed for statistical significance using the two‐sample test of proportions.</p> </sec> <sec id="jmri24198-sec-0003" sec-type="section"> <title>Results</title> <p>There were 495 screening breast MRI exams. There were 419 (84.6%) BI‐RADS 1/2 results, 35 (7.1%) BI‐RADS 3 results, and 41 (8.3%) BI‐RADS 4/5 results. BI‐RADS 4/5 results increased at 3T (<italic>P</italic> = 0.04). The positive predictive value for BI‐RADS 4/5 was 29.3% (12/41) at 3T, compared with 17.6% at 1.5T (<italic>P</italic> &lt; 0.001). Cancer detection rate was 2.6% at 3T, compared with 0.9% at 1.5T (<italic>P</italic> = 0.02).</p> </sec> <sec id="jmri24198-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Transition to 3T breast MRI in a screening population resulted in increased BI‐RADS 4/5 interpretations, positive predictive value of biopsy recommendations, and cancer detection rate. <bold>J. Magn. Reson. Imaging 2014;39:535–539</bold>. © <bold>2013 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 39:Issue 3(2014)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 39:Issue 3(2014)
- Issue Display:
- Volume 39, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 39
- Issue:
- 3
- Issue Sort Value:
- 2014-0039-0003-0000
- Page Start:
- 535
- Page End:
- 539
- Publication Date:
- 2013-05-29
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24198 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3093.xml