Hybrid multidimensional T2 and diffusion‐weighted MRI for prostate cancer detection. Issue 4 (1st August 2013)
- Record Type:
- Journal Article
- Title:
- Hybrid multidimensional T2 and diffusion‐weighted MRI for prostate cancer detection. Issue 4 (1st August 2013)
- Main Title:
- Hybrid multidimensional T2 and diffusion‐weighted MRI for prostate cancer detection
- Authors:
- Wang, Shiyang
Peng, Yahui
Medved, Milica
Yousuf, Ambereen N.
Ivancevic, Marko K.
Karademir, Ibrahim
Jiang, Yulei
Antic, Tatjana
Sammet, Steffen
Oto, Aytekin
Karczmar, Gregory S. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24212-sec-0001" sec-type="section"> <title>Purpose</title> <p>To study the dependence of apparent diffusion coefficient (ADC) and T<sub>2</sub> on echo time (TE) and b‐value, respectively, in normal prostate and prostate cancer, using two‐dimensional MRI sampling, referred to as "hybrid multidimensional imaging."</p> </sec> <sec id="jmri24212-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>The study included 10 patients with biopsy‐proven prostate cancer who underwent 3 Tesla prostate MRI. Diffusion‐weighted MRI (DWI) data were acquired at b = 0, 750, and 1500 s/mm<sup>2</sup>. For each b‐value, data were acquired at TEs of 47, 75, and 100 ms. ADC and T<sub>2</sub> were measured as a function of b‐value and TE, respectively, in 15 cancer and 10 normal regions of interest (ROIs). The Friedman test was used to test the significance of changes in ADC as a function of TE and of T<sub>2</sub> as a function of b‐value.</p> </sec> <sec id="jmri24212-sec-0003" sec-type="section"> <title>Results</title> <p>In normal prostate ROIs, the ADC at TE of 47 ms is significantly smaller than ADC at TE of 100 ms (<italic>P</italic> = 0.0003) and T<sub>2</sub> at b‐value of 0 s/mm<sup>2</sup> is significantly longer than T<sub>2</sub> at b‐value of 1500 s/mm<sup>2</sup> (<italic>P</italic> = 0.001). In cancer ROIs, average ADC and T<sub>2</sub> values do not change as a<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24212-sec-0001" sec-type="section"> <title>Purpose</title> <p>To study the dependence of apparent diffusion coefficient (ADC) and T<sub>2</sub> on echo time (TE) and b‐value, respectively, in normal prostate and prostate cancer, using two‐dimensional MRI sampling, referred to as "hybrid multidimensional imaging."</p> </sec> <sec id="jmri24212-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>The study included 10 patients with biopsy‐proven prostate cancer who underwent 3 Tesla prostate MRI. Diffusion‐weighted MRI (DWI) data were acquired at b = 0, 750, and 1500 s/mm<sup>2</sup>. For each b‐value, data were acquired at TEs of 47, 75, and 100 ms. ADC and T<sub>2</sub> were measured as a function of b‐value and TE, respectively, in 15 cancer and 10 normal regions of interest (ROIs). The Friedman test was used to test the significance of changes in ADC as a function of TE and of T<sub>2</sub> as a function of b‐value.</p> </sec> <sec id="jmri24212-sec-0003" sec-type="section"> <title>Results</title> <p>In normal prostate ROIs, the ADC at TE of 47 ms is significantly smaller than ADC at TE of 100 ms (<italic>P</italic> = 0.0003) and T<sub>2</sub> at b‐value of 0 s/mm<sup>2</sup> is significantly longer than T<sub>2</sub> at b‐value of 1500 s/mm<sup>2</sup> (<italic>P</italic> = 0.001). In cancer ROIs, average ADC and T<sub>2</sub> values do not change as a function of TE and b‐value, respectively. However, in many cancer pixels, there are large decreases in the ADC as a function of TE and large increases in T<sub>2</sub> as a function of b‐value. Cancers are more conspicuous in ADC maps at longer TEs.</p> </sec> <sec id="jmri24212-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Parameters derived from hybrid imaging that depend on coupled/associated values of ADC and T<sub>2</sub> may improve the accuracy of MRI in diagnosing prostate cancer. <bold>J. Magn. Reson. Imaging 2014;39:781–788.</bold> © <bold>2013 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 39:Issue 4(2014)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 39:Issue 4(2014)
- Issue Display:
- Volume 39, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 39
- Issue:
- 4
- Issue Sort Value:
- 2014-0039-0004-0000
- Page Start:
- 781
- Page End:
- 788
- Publication Date:
- 2013-08-01
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24212 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3037.xml