Diagnostic accuracy of 18F‐methylcholine positron emission tomography/computed tomography for intra‐ and extrahepatic hepatocellular carcinoma. Issue 3 (30th January 2014)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of 18F‐methylcholine positron emission tomography/computed tomography for intra‐ and extrahepatic hepatocellular carcinoma. Issue 3 (30th January 2014)
- Main Title:
- Diagnostic accuracy of 18F‐methylcholine positron emission tomography/computed tomography for intra‐ and extrahepatic hepatocellular carcinoma
- Authors:
- Bieze, Matthanja
Klümpen, Heinz‐Josef
Verheij, Joanne
Beuers, Ulrich
Phoa, Saffire S.K.S.
van Gulik, Thomas M.
Bennink, Roelof J. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Diagnosis of hepatocellular carcinoma (HCC) primarily involves imaging. The aim of this study was to assess the accuracy of <sup>18</sup>F‐fluorocholine (<sup>18</sup>F‐FCH) positron emission tomography (PET) for detection of HCC and evaluation of extent of disease. Patients with HCC &gt;1 cm were included between 2009 and July 2011, and follow‐up closed in February 2013. Diagnosis was based on American Association for the Study of Liver Diseases criteria, and all patients underwent <sup>18</sup>F‐FCH PET/computed tomography (CT) at baseline before treatment, 6 underwent a second PET/CT posttreatment, and 1 a third during follow‐up. Whole‐body PET and low‐dose CT imaging were performed 15 minutes after <sup>18</sup>F‐FCH injection. Evaluation of imaging was done with standardized uptake value (SUV) ratios: SUV maximum of the lesion divided by the SUV mean of surrounding tissue. Statistical analyses included descriptive analyses, receiver operating characteristic curve, McNemar's test, and Kaplan‐Meier's test at 5% level of significance. Twenty‐nine patients revealed 53 intrahepatic lesions. In 48 of 53 lesions, <sup>18</sup>F‐FCH PET was positive (SUV<sub>ratio</sub>, 1.95 ± 0.66; sensitivity, 88%; specificity, 100%). PET/CT showed uptake in 18 extrahepatic lesions and no uptake in 3 lesions affirmed non‐HCC lesions; all lesions were confirmed with additional investigation (accuracy,<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Diagnosis of hepatocellular carcinoma (HCC) primarily involves imaging. The aim of this study was to assess the accuracy of <sup>18</sup>F‐fluorocholine (<sup>18</sup>F‐FCH) positron emission tomography (PET) for detection of HCC and evaluation of extent of disease. Patients with HCC &gt;1 cm were included between 2009 and July 2011, and follow‐up closed in February 2013. Diagnosis was based on American Association for the Study of Liver Diseases criteria, and all patients underwent <sup>18</sup>F‐FCH PET/computed tomography (CT) at baseline before treatment, 6 underwent a second PET/CT posttreatment, and 1 a third during follow‐up. Whole‐body PET and low‐dose CT imaging were performed 15 minutes after <sup>18</sup>F‐FCH injection. Evaluation of imaging was done with standardized uptake value (SUV) ratios: SUV maximum of the lesion divided by the SUV mean of surrounding tissue. Statistical analyses included descriptive analyses, receiver operating characteristic curve, McNemar's test, and Kaplan‐Meier's test at 5% level of significance. Twenty‐nine patients revealed 53 intrahepatic lesions. In 48 of 53 lesions, <sup>18</sup>F‐FCH PET was positive (SUV<sub>ratio</sub>, 1.95 ± 0.66; sensitivity, 88%; specificity, 100%). PET/CT showed uptake in 18 extrahepatic lesions and no uptake in 3 lesions affirmed non‐HCC lesions; all lesions were confirmed with additional investigation (accuracy, 100%). In 17 of 29 patients, additional lesions were found on PET/CT imaging, with implications for treatment in 15 patients. Posttreatment PET/CT showed identical results, compared with standard treatment evaluation. <italic>Conclusion</italic>: This study shows additional value of <sup>18</sup>F‐FCH PET/CT for patients with HCC. <sup>18</sup>F‐FCH PET/CT has implications for staging, management, and treatment evaluation because of accurate assessment of extrahepatic disease. (H<sc>epatology</sc> 2014;59:996–1006)</p> </abstract> … (more)
- Is Part Of:
- Hepatology. Volume 59:Issue 3(2014:Mar.)
- Journal:
- Hepatology
- Issue:
- Volume 59:Issue 3(2014:Mar.)
- Issue Display:
- Volume 59, Issue 3 (2014)
- Year:
- 2014
- Volume:
- 59
- Issue:
- 3
- Issue Sort Value:
- 2014-0059-0003-0000
- Page Start:
- 996
- Page End:
- 1006
- Publication Date:
- 2014-01-30
- Subjects:
- Heart -- Diseases -- Nursing -- Periodicals
Lungs -- Diseases -- Nursing -- Periodicals
Intensive care nursing -- Periodicals
Foie -- Maladies -- Périodiques
616.362 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1527-3350 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/hep.26781 ↗
- Languages:
- English
- ISSNs:
- 0270-9139
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4295.836000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4221.xml