Posttransfusion platelet increments after different platelet products in neonates: a retrospective cohort study. Issue 12 (26th February 2013)
- Record Type:
- Journal Article
- Title:
- Posttransfusion platelet increments after different platelet products in neonates: a retrospective cohort study. Issue 12 (26th February 2013)
- Main Title:
- Posttransfusion platelet increments after different platelet products in neonates: a retrospective cohort study
- Authors:
- Honohan, Áine
van't, Ella
Hulzebos, Christian
Lopriore, Enrico
van't, Ellen
Govaert, Paul
Brand, Anneke
van der, Johanna - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="trf12127-sec-0001" sec-type="section"> <title>Background</title> <p>In the Netherlands different platelet (PLT) products are used for neonatal transfusions: volume‐reduced PLTs, PLT additive solution (PAS) II PLTs, and plasma PLTs. These are standard products at three different neonatal intensive care units where local transfusion guidelines apply. Here we assess the posttransfusion count increments with these products.</p> </sec> <sec id="trf12127-sec-0002" sec-type="section"> <title>Study Design and Methods</title> <p>We performed a retrospective cohort study of neonates who received, in the first month after birth, between January 1, 2007, and December 31, 2008, at least one PLT transfusion. Seventy‐four neonates who received 197 volume‐reduced PLTs transfusions, 68 neonates who received 105 PASII PLT transfusions, and eight neonates who received eight plasma PLT transfusions were analyzed. Early (within 8 hr after transfusion) and follow‐up count increments (16‐24 hr after transfusion) were evaluated for 191 and 81 volume‐reduced PLTs, 77 and 56 PASII PLTs, and six and five plasma PLT transfusions, respectively, using a random‐effects model.</p> </sec> <sec id="trf12127-sec-0003" sec-type="section"> <title>Results</title> <p>Volume‐reduced PLTs were transfused at twice the dose in one‐fifth the volume of PASII and plasma PLTs. The early posttransfusion count increment was<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="trf12127-sec-0001" sec-type="section"> <title>Background</title> <p>In the Netherlands different platelet (PLT) products are used for neonatal transfusions: volume‐reduced PLTs, PLT additive solution (PAS) II PLTs, and plasma PLTs. These are standard products at three different neonatal intensive care units where local transfusion guidelines apply. Here we assess the posttransfusion count increments with these products.</p> </sec> <sec id="trf12127-sec-0002" sec-type="section"> <title>Study Design and Methods</title> <p>We performed a retrospective cohort study of neonates who received, in the first month after birth, between January 1, 2007, and December 31, 2008, at least one PLT transfusion. Seventy‐four neonates who received 197 volume‐reduced PLTs transfusions, 68 neonates who received 105 PASII PLT transfusions, and eight neonates who received eight plasma PLT transfusions were analyzed. Early (within 8 hr after transfusion) and follow‐up count increments (16‐24 hr after transfusion) were evaluated for 191 and 81 volume‐reduced PLTs, 77 and 56 PASII PLTs, and six and five plasma PLT transfusions, respectively, using a random‐effects model.</p> </sec> <sec id="trf12127-sec-0003" sec-type="section"> <title>Results</title> <p>Volume‐reduced PLTs were transfused at twice the dose in one‐fifth the volume of PASII and plasma PLTs. The early posttransfusion count increment was higher for volume‐reduced PLTs at 111 × 10<sup>9</sup>/L (95% confidence interval [CI], 86‐135) compared to PASII PLTs at 62 × 10<sup>9</sup>/L (95% CI, 40‐84; p = 0.000) and plasma PLTs at 47 × 10<sup>9</sup>/L (95% CI, 14‐79). The follow‐up count increment was also higher for volume‐reduced PLTs at 60 × 10<sup>9</sup>/L (95% CI, 19‐100) compared to PASII PLTs at 38 × 10<sup>9</sup>/L (95% CI, −0.2 to 77; p = 0.082) and plasma PLTs at 4 × 10<sup>9</sup>/L (95% CI, −38 to 46).</p> </sec> <sec id="trf12127-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Neonates who received twice the PLT dose by volume‐reduced PLTs had twice as high early and follow‐up count increment showing similar efficacy of products.</p> </sec> </abstract> … (more)
- Is Part Of:
- Transfusion. Volume 53:Issue 12(2013)
- Journal:
- Transfusion
- Issue:
- Volume 53:Issue 12(2013)
- Issue Display:
- Volume 53, Issue 12 (2013)
- Year:
- 2013
- Volume:
- 53
- Issue:
- 12
- Issue Sort Value:
- 2013-0053-0012-0000
- Page Start:
- 3100
- Page End:
- 3109
- Publication Date:
- 2013-02-26
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.12127 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3876.xml