Lot‐to‐lot variability in HLA antibody screening using a multiplexed bead‐based assay. Issue 9 (10th January 2013)
- Record Type:
- Journal Article
- Title:
- Lot‐to‐lot variability in HLA antibody screening using a multiplexed bead‐based assay. Issue 9 (10th January 2013)
- Main Title:
- Lot‐to‐lot variability in HLA antibody screening using a multiplexed bead‐based assay
- Authors:
- Gandhi, Manish J.
Carrick, Danielle M.
Jenkins, Sarah
De Goey, Steven
Ploeger, Nancy A.
Wilson, Gregory A.
Lee, Jar How
Winters, Jeffrey L.
Stubbs, James R.
Toy, Pearl
Norris, Philip J. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="trf12064-sec-0001" sec-type="section"> <title>Background</title> <p>Identifying antibodies to HLA (anti‐HLA) by solid‐phase assays is used to screen blood donors to mitigate transfusion‐related acute lung injury risk. Various cutoffs for detection assays have been proposed in the literature; however, these do not take into consideration lot‐to‐lot variability of commercially available assays.</p> </sec> <sec id="trf12064-sec-0002" sec-type="section"> <title>Study Design and Methods</title> <p>Samples from 93 nontransfused males were tested using five different lots of a multiplex bead‐based anti‐HLA detection kit. A subset of 17 samples was tested on 5 days using a single lot. An additional 96 samples from donations with varied anti‐HLA levels were tested using kits from two different lots. Results were reported as a normalized background (NBG) ratio.</p> </sec> <sec id="trf12064-sec-0003" sec-type="section"> <title>Results</title> <p>For the 93 nontransfused donors, NBG values generated using the reference lot were significantly higher than those obtained with three of the four comparator lots. However, for the 96 samples with low‐, moderate‐, and higher‐level anti‐HLA, Class I (CL‐I) values were 1.4 times lower and Class II (CL‐II) values were 1.2 times lower using the reference versus comparator lot. For CL‐I antibodies the between‐lot standard deviation (SD) was 1.36 (95%<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="trf12064-sec-0001" sec-type="section"> <title>Background</title> <p>Identifying antibodies to HLA (anti‐HLA) by solid‐phase assays is used to screen blood donors to mitigate transfusion‐related acute lung injury risk. Various cutoffs for detection assays have been proposed in the literature; however, these do not take into consideration lot‐to‐lot variability of commercially available assays.</p> </sec> <sec id="trf12064-sec-0002" sec-type="section"> <title>Study Design and Methods</title> <p>Samples from 93 nontransfused males were tested using five different lots of a multiplex bead‐based anti‐HLA detection kit. A subset of 17 samples was tested on 5 days using a single lot. An additional 96 samples from donations with varied anti‐HLA levels were tested using kits from two different lots. Results were reported as a normalized background (NBG) ratio.</p> </sec> <sec id="trf12064-sec-0003" sec-type="section"> <title>Results</title> <p>For the 93 nontransfused donors, NBG values generated using the reference lot were significantly higher than those obtained with three of the four comparator lots. However, for the 96 samples with low‐, moderate‐, and higher‐level anti‐HLA, Class I (CL‐I) values were 1.4 times lower and Class II (CL‐II) values were 1.2 times lower using the reference versus comparator lot. For CL‐I antibodies the between‐lot standard deviation (SD) was 1.36 (95% confidence interval [CI], 1.19‐1.60), while the between‐day SD was 1.27 (95% CI, 1.08‐1.52). Similarly, for CL‐II antibodies the between‐lot SD was 0.81 (95% CI, 0.70‐0.95), while the between‐day SD was 0.50 (95% CI, 0.43‐0.60).</p> </sec> <sec id="trf12064-sec-0004" sec-type="section"> <title>Conclusions</title> <p>There is interlot variability in the tested HLA detection assay as well as significant bias between lots. It may be reasonable to develop a new cutoff when a new lot is obtained.</p> </sec> </abstract> … (more)
- Is Part Of:
- Transfusion. Volume 53:Issue 9(2013)
- Journal:
- Transfusion
- Issue:
- Volume 53:Issue 9(2013)
- Issue Display:
- Volume 53, Issue 9 (2013)
- Year:
- 2013
- Volume:
- 53
- Issue:
- 9
- Issue Sort Value:
- 2013-0053-0009-0000
- Page Start:
- 1940
- Page End:
- 1947
- Publication Date:
- 2013-01-10
- Subjects:
- Hematology -- Periodicals
Blood -- Transfusion -- Periodicals
Blood Group Antigens -- Periodicals
Blood Preservation -- Periodicals
Blood Transfusion -- Periodicals
615 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1537-2995 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=trf ↗
http://www.transfusion.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/trf.12064 ↗
- Languages:
- English
- ISSNs:
- 0041-1132
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4315.xml