A method for evaluating the use of fluorescent dyes to track proliferation in cell lines by dye dilution. Issue 12 (25th October 2013)
- Record Type:
- Journal Article
- Title:
- A method for evaluating the use of fluorescent dyes to track proliferation in cell lines by dye dilution. Issue 12 (25th October 2013)
- Main Title:
- A method for evaluating the use of fluorescent dyes to track proliferation in cell lines by dye dilution
- Authors:
- Begum, Julfa
Day, William
Henderson, Carl
Purewal, Sukhveer
Cerveira, Joana
Summers, Huw
Rees, Paul
Davies, Derek
Filby, Andrew - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Labeling nonquiescent cells with carboxyfluorescein succinimidyl ester (CFSE)‐like dyes gives rise to a population width exceeding the threshold for resolving division peaks by flow cytometry. Width is a function of biological heterogeneity plus extrinsic and intrinsic error sources associated with the measurement process. Optimal cytometer performance minimizes extrinsic error, but reducing intrinsic error to the point of facilitating peak resolution requires careful fluorochrome selection and fluorescent cell sorting. In this study, we labeled the Jurkat and A549 cell lines with CFSE, CellTraceViolet (CTV), and eFluor 670 proliferation dye (EPD) to test if we could resolve division peaks in culture after reducing the labeled input widths by cell sorting. Reanalysis of the sorted populations to ascertain the level of reduction achieved always led to widths exceeding the gated limits due to the contribution of errors. Measuring detector‐specific extrinsic error by sorting uniform fluorescent particles with similar spectral properties to the tracking dyes allowed us to determine the intrinsic error for each dye and cell type using a simple mathematical approach. We found that cell intrinsic error ultimately dictated whether we could resolve division peaks, and that as this increased, the required sort gate width to resolve any division peaks decreased to the point whereby issues with yield made A549 unsuitable for<abstract abstract-type="main"> <title>Abstract</title> <p>Labeling nonquiescent cells with carboxyfluorescein succinimidyl ester (CFSE)‐like dyes gives rise to a population width exceeding the threshold for resolving division peaks by flow cytometry. Width is a function of biological heterogeneity plus extrinsic and intrinsic error sources associated with the measurement process. Optimal cytometer performance minimizes extrinsic error, but reducing intrinsic error to the point of facilitating peak resolution requires careful fluorochrome selection and fluorescent cell sorting. In this study, we labeled the Jurkat and A549 cell lines with CFSE, CellTraceViolet (CTV), and eFluor 670 proliferation dye (EPD) to test if we could resolve division peaks in culture after reducing the labeled input widths by cell sorting. Reanalysis of the sorted populations to ascertain the level of reduction achieved always led to widths exceeding the gated limits due to the contribution of errors. Measuring detector‐specific extrinsic error by sorting uniform fluorescent particles with similar spectral properties to the tracking dyes allowed us to determine the intrinsic error for each dye and cell type using a simple mathematical approach. We found that cell intrinsic error ultimately dictated whether we could resolve division peaks, and that as this increased, the required sort gate width to resolve any division peaks decreased to the point whereby issues with yield made A549 unsuitable for this approach. Finally, attempts to improve yields by setting two concurrent sort gates on the fluorescence distribution enriched for cells in different stages of the cell cycle that had nonequivalent proliferative properties in culture and thus should be practiced with caution. © 2013 International Society for Advancement of Cytometry</p> </abstract> … (more)
- Is Part Of:
- Cytometry. Volume 83:Issue 12(2013:Dec.)
- Journal:
- Cytometry
- Issue:
- Volume 83:Issue 12(2013:Dec.)
- Issue Display:
- Volume 83, Issue 12 (2013)
- Year:
- 2013
- Volume:
- 83
- Issue:
- 12
- Issue Sort Value:
- 2013-0083-0012-0000
- Page Start:
- 1085
- Page End:
- 1095
- Publication Date:
- 2013-10-25
- Subjects:
- Flow cytometry -- Periodicals
Imaging systems in biology -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnostic imaging -- Periodicals
571.605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4930 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cyto.a.22403 ↗
- Languages:
- English
- ISSNs:
- 1552-4922
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: