Comparison and evaluation of seven different bench‐top flow cytometers with a modified six‐plexed mycotoxin kit. Issue 12 (3rd September 2013)
- Record Type:
- Journal Article
- Title:
- Comparison and evaluation of seven different bench‐top flow cytometers with a modified six‐plexed mycotoxin kit. Issue 12 (3rd September 2013)
- Main Title:
- Comparison and evaluation of seven different bench‐top flow cytometers with a modified six‐plexed mycotoxin kit
- Authors:
- Czeh, Arpad
Schwartz, Abe
Mandy, Frank
Szoke, Zsuzsanna
Koszegi, Balazs
Feher‐Toth, Szilvia
Nagyeri, Gyorgy
Jakso, Pal
Katona, Robert L.
Kemeny, Agnes
Woth, Gabor
Lustyik, Gyorgy - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Many bench‐top flow cytometers (b‐FCs) are compatible with microsphere‐based multiplexed assays. Disciplines implementing b‐FCs–based assays are expanding; they include monitoring and validating food quality. A multiplexed platform protocol was evaluated for poly‐mycotoxin assays, which is compatible with a variety of b‐FC models. The seven instruments included: BD FACSCalibur<sup>™</sup>, BD FACSArray<sup>™</sup> Bioanalyzer, Accuri C6, Partec CyFlow<sup>®</sup> Space, Beckman Coulter FC 500, Guava EasyCyte Mini, and Luminex 100 <sup>™</sup>. Current reports related to the food industry describe fungal co‐infections leading to poly‐mycotoxin contamination in grain (Sulyok M, Berthiller F, Krska R, Schuhmacher R, Rapid Commun Mass Spectrom 2006;20:2649–2659). It is imperative to determine whether b‐FC–based assays can replace traditional single‐mycotoxin enzyme‐linked immunosorbent assay (ELISA). A six‐plexed poly‐mycotoxin kit was tested on seven different b‐FCs. The modified kit was initially developed for the BD FACSArray<sup>™</sup> Bioanalyzer (BD Biosciences) (Czeh A, Mandy F, Feher‐Toth S, Torok L, Mike Z, Koszegi B, Lustyik G, J Immunol Methods 2012;384:71–80). With the multiplexed platform, it is possible to identify up to six mycotoxin contaminants simultaneously at regional grain collection/transfer/inspection facilities. In the future, elimination of contaminated food threat may be better achieved with<abstract abstract-type="main"> <title>Abstract</title> <p>Many bench‐top flow cytometers (b‐FCs) are compatible with microsphere‐based multiplexed assays. Disciplines implementing b‐FCs–based assays are expanding; they include monitoring and validating food quality. A multiplexed platform protocol was evaluated for poly‐mycotoxin assays, which is compatible with a variety of b‐FC models. The seven instruments included: BD FACSCalibur<sup>™</sup>, BD FACSArray<sup>™</sup> Bioanalyzer, Accuri C6, Partec CyFlow<sup>®</sup> Space, Beckman Coulter FC 500, Guava EasyCyte Mini, and Luminex 100 <sup>™</sup>. Current reports related to the food industry describe fungal co‐infections leading to poly‐mycotoxin contamination in grain (Sulyok M, Berthiller F, Krska R, Schuhmacher R, Rapid Commun Mass Spectrom 2006;20:2649–2659). It is imperative to determine whether b‐FC–based assays can replace traditional single‐mycotoxin enzyme‐linked immunosorbent assay (ELISA). A six‐plexed poly‐mycotoxin kit was tested on seven different b‐FCs. The modified kit was initially developed for the BD FACSArray<sup>™</sup> Bioanalyzer (BD Biosciences) (Czeh A, Mandy F, Feher‐Toth S, Torok L, Mike Z, Koszegi B, Lustyik G, J Immunol Methods 2012;384:71–80). With the multiplexed platform, it is possible to identify up to six mycotoxin contaminants simultaneously at regional grain collection/transfer/inspection facilities. In the future, elimination of contaminated food threat may be better achieved with the inclusion of b‐FCs in the food protection arsenal. A universal protocol, matched with postacquisition software, offers an effective alternative platform compared to using a series of ELISA kits. To support side‐by‐side evaluation of seven flow cytometers, an instrument‐independent fluorescence emission calibration was added to the protocol. All instrument performances were evaluated for strength of agreement based on paired sets of evaluation to predicate method. The results suggest that all b‐FCs were acceptable of performing with the multiplexed kit for five of six mycotoxins. For OTA, the detection sensitivity was consistent only for five of the seven instruments. © 2013 International Society for Advancement of Cytometry</p> </abstract> … (more)
- Is Part Of:
- Cytometry. Volume 83:Issue 12(2013:Dec.)
- Journal:
- Cytometry
- Issue:
- Volume 83:Issue 12(2013:Dec.)
- Issue Display:
- Volume 83, Issue 12 (2013)
- Year:
- 2013
- Volume:
- 83
- Issue:
- 12
- Issue Sort Value:
- 2013-0083-0012-0000
- Page Start:
- 1073
- Page End:
- 1084
- Publication Date:
- 2013-09-03
- Subjects:
- Flow cytometry -- Periodicals
Imaging systems in biology -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnostic imaging -- Periodicals
571.605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4930 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cyto.a.22335 ↗
- Languages:
- English
- ISSNs:
- 1552-4922
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3158.xml