Analytic Evaluation of a Human ELISA Kit for Measurement of Inhibin B in Rat Samples. (24th January 2013)
- Record Type:
- Journal Article
- Title:
- Analytic Evaluation of a Human ELISA Kit for Measurement of Inhibin B in Rat Samples. (24th January 2013)
- Main Title:
- Analytic Evaluation of a Human ELISA Kit for Measurement of Inhibin B in Rat Samples
- Authors:
- Coulson, Michelle
Bickerton, Sue
Betts, Catherine J
Jacobsen, Matt
Stewart, Jane
Chapin, Robert E.
Reagan, William J.
Alvey, James
Erdos, Zoltan
Saldutti, Louise Parks
Sonee, Manisha
Bogdan, Nancy
Singer, Monica
Vinken, Petra
Barlow, Valerie
Czajkowski, Karen
Kim, James H. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="bdrb21047-sec-0010" sec-type="section"> <title>BACKGROUND</title> <p>A cross‐laboratory analytic evaluation of a commercially available human inhibin B ELISA for measuring inhibin B in rat serum and plasma has been undertaken.</p> </sec> <sec id="bdrb21047-sec-0020" sec-type="section"> <title>METHODS</title> <p>Dilution linearity, spiked recovery, intra‐ and inter‐assay precision, functional sensitivity, matrix effects, and frozen stability were assessed across five laboratories. Reference ranges were generated for male Sprague Dawley and Han Wistar rats.</p> </sec> <sec id="bdrb21047-sec-0030" sec-type="section"> <title>RESULTS</title> <p>Acceptable performance was defined as an overall assay coefficient of variation ≤ 20% with an intraday LLOQ ≤ 20 pg/ml. Intra‐ and inter‐assay precision and functional sensitivity (≤6.4 pg/ml) generally met these criteria, but with occasional evidence of greater variability, particularly at lower concentrations. Dilution linearity was acceptable with occasional low recovery. Acceptable recovery of kit calibrators from rat serum confirmed the absence of matrix effects. Matched serum and plasma samples gave comparable results. The signal increased on freezing, remained constant for ≥3 freeze‐thaw cycles and was generally stable for at least 8 weeks. Mean inhibin B ranged from 33.5 to 140.6 pg/ml in adult rats across laboratories, with some evidence<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="bdrb21047-sec-0010" sec-type="section"> <title>BACKGROUND</title> <p>A cross‐laboratory analytic evaluation of a commercially available human inhibin B ELISA for measuring inhibin B in rat serum and plasma has been undertaken.</p> </sec> <sec id="bdrb21047-sec-0020" sec-type="section"> <title>METHODS</title> <p>Dilution linearity, spiked recovery, intra‐ and inter‐assay precision, functional sensitivity, matrix effects, and frozen stability were assessed across five laboratories. Reference ranges were generated for male Sprague Dawley and Han Wistar rats.</p> </sec> <sec id="bdrb21047-sec-0030" sec-type="section"> <title>RESULTS</title> <p>Acceptable performance was defined as an overall assay coefficient of variation ≤ 20% with an intraday LLOQ ≤ 20 pg/ml. Intra‐ and inter‐assay precision and functional sensitivity (≤6.4 pg/ml) generally met these criteria, but with occasional evidence of greater variability, particularly at lower concentrations. Dilution linearity was acceptable with occasional low recovery. Acceptable recovery of kit calibrators from rat serum confirmed the absence of matrix effects. Matched serum and plasma samples gave comparable results. The signal increased on freezing, remained constant for ≥3 freeze‐thaw cycles and was generally stable for at least 8 weeks. Mean inhibin B ranged from 33.5 to 140.6 pg/ml in adult rats across laboratories, with some evidence for a decline from 6 to 9 weeks of age. Power calculations using preliminary reference range data indicated 10 animals/group would generally detect a 40% decrease in inhibin B at AstraZeneca, but laboratories with lower control values would require larger groups.</p> </sec> <sec id="bdrb21047-sec-0040" sec-type="section"> <title>CONCLUSIONS</title> <p>The assay meets the analytical performance criteria; however, precision at the low end of the standard curve, biological variability, and low control values observed in some laboratories indicate that the utility of the assay may be limited in some laboratories.</p> </sec> </abstract> … (more)
- Is Part Of:
- Birth defects research. Volume 98:Number 1(2013)
- Journal:
- Birth defects research
- Issue:
- Volume 98:Number 1(2013)
- Issue Display:
- Volume 98, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 98
- Issue:
- 1
- Issue Sort Value:
- 2013-0098-0001-0000
- Page Start:
- 4
- Page End:
- 16
- Publication Date:
- 2013-01-24
- Subjects:
- Developmental toxicology -- Periodicals
Reproductive toxicology -- Periodicals
616.65071 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bdrb.21047 ↗
- Languages:
- English
- ISSNs:
- 1542-9733
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2094.091500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4027.xml