The effect of cell subset isolation method on gene expression in leukocytes. Issue 1 (20th September 2013)
- Record Type:
- Journal Article
- Title:
- The effect of cell subset isolation method on gene expression in leukocytes. Issue 1 (20th September 2013)
- Main Title:
- The effect of cell subset isolation method on gene expression in leukocytes
- Authors:
- Beliakova‐Bethell, Nadejda
Massanella, Marta
White, Cory
Lada, Steven M.
Du, Pinyi
Vaida, Florin
Blanco, Julià
Spina, Celsa A.
Woelk, Christopher H. - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Multiple scientific disciplines require the isolation of specific subsets of blood cells from patient samples for gene expression analysis by microarray or RNA‐sequencing, preserving disease‐ or treatment‐related signatures. However, little is known with respect to the impact of different cell isolation methods on gene expression and the effects of positive selection, negative selection, and fluorescence activated cell sorting (FACS) have not previously been assessed in parallel. To address this knowledge gap, CD4+ T cells, CD8+ T cells, B cells, and monocytes were isolated from blood samples from five independent donors using positive immunomagnetic selection, negative immunomagnetic selection, and FACS. We hypothesized that positive selection and FACS would yield higher purity but may have an impact on gene expression since both methods utilize antibodies that bind surface receptors of the cell type of interest. Moreover, FACS might upregulate stress response genes due to passage of the cells through the sorter. Microarray gene expression data were generated and subjected to unsupervised clustering and differential gene expression analysis. Surprisingly, these analyses revealed that gene expression signatures were more similar between cells isolated by negative selection and FACS compared to cells isolated by positive selection. Moreover, genes that are involved in the response to stress generally had the highest<abstract abstract-type="main"> <title>Abstract</title> <p>Multiple scientific disciplines require the isolation of specific subsets of blood cells from patient samples for gene expression analysis by microarray or RNA‐sequencing, preserving disease‐ or treatment‐related signatures. However, little is known with respect to the impact of different cell isolation methods on gene expression and the effects of positive selection, negative selection, and fluorescence activated cell sorting (FACS) have not previously been assessed in parallel. To address this knowledge gap, CD4+ T cells, CD8+ T cells, B cells, and monocytes were isolated from blood samples from five independent donors using positive immunomagnetic selection, negative immunomagnetic selection, and FACS. We hypothesized that positive selection and FACS would yield higher purity but may have an impact on gene expression since both methods utilize antibodies that bind surface receptors of the cell type of interest. Moreover, FACS might upregulate stress response genes due to passage of the cells through the sorter. Microarray gene expression data were generated and subjected to unsupervised clustering and differential gene expression analysis. Surprisingly, these analyses revealed that gene expression signatures were more similar between cells isolated by negative selection and FACS compared to cells isolated by positive selection. Moreover, genes that are involved in the response to stress generally had the highest expression in cells isolated by negative or positive selection and not FACS. Thus, FACS is the recommended method for isolation of leukocyte subsets for gene expression studies since this method results in the purest subset populations and does not appear to induce a stress response. © 2013 International Society for Advancement of Cytometry</p> </abstract> … (more)
- Is Part Of:
- Cytometry. Volume 85:Issue 1(2014:Jan.)
- Journal:
- Cytometry
- Issue:
- Volume 85:Issue 1(2014:Jan.)
- Issue Display:
- Volume 85, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 85
- Issue:
- 1
- Issue Sort Value:
- 2014-0085-0001-0000
- Page Start:
- 94
- Page End:
- 104
- Publication Date:
- 2013-09-20
- Subjects:
- Flow cytometry -- Periodicals
Imaging systems in biology -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnostic imaging -- Periodicals
571.605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4930 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cyto.a.22352 ↗
- Languages:
- English
- ISSNs:
- 1552-4922
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3317.xml