On‐coil multiple channel transmit system based on class‐D amplification and pre‐amplification with current amplitude feedback. Issue 1 (13th August 2012)
- Record Type:
- Journal Article
- Title:
- On‐coil multiple channel transmit system based on class‐D amplification and pre‐amplification with current amplitude feedback. Issue 1 (13th August 2012)
- Main Title:
- On‐coil multiple channel transmit system based on class‐D amplification and pre‐amplification with current amplitude feedback
- Authors:
- Gudino, Natalia
Heilman, Jeremiah A.
Riffe, Matthew J.
Heid, Oliver
Vester, Markus
Griswold, Mark A. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>A complete high‐efficiency transmit amplifier unit designed to be implemented in on‐coil transmit arrays is presented. High power capability, low power dissipation, scalability, and cost minimization were some of the requirements imposed to the design. The system is composed of a current mode class‐D amplifier output stage and a voltage mode class‐D preamplification stage. The amplitude information of the radio frequency pulse was added through a customized step‐down DC‐DC converter with current amplitude feedback that connects to the current mode class‐D stage. Benchtop measurements and imaging experiments were carried out to analyze system performance. Direct control of <italic>B</italic><sub>1</sub> was possible and its load sensitivity was reduced to less than 10% variation from unloaded to full loaded condition. When using the amplifiers in an array configuration, isolation above 20 dB was achieved between neighboring coils by the amplifier decoupling method. High output current operation of the transmitter was proved on the benchtop through output power measurements and in a 1.5T scanner through flip angle quantification. Finally, single and multiple channel excitations with the new hardware were demonstrated by receiving signal with the body coil of the scanner. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</p> </abstract>
- Is Part Of:
- Magnetic resonance in medicine. Volume 70:Issue 1(2013:Jul.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 70:Issue 1(2013:Jul.)
- Issue Display:
- Volume 70, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 70
- Issue:
- 1
- Issue Sort Value:
- 2013-0070-0001-0000
- Page Start:
- 276
- Page End:
- 289
- Publication Date:
- 2012-08-13
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24462 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3865.xml