Perfusion phantom: An efficient and reproducible method to simulate myocardial first‐pass perfusion measurements with cardiovascular magnetic resonance†. Issue 3 (24th April 2012)
- Record Type:
- Journal Article
- Title:
- Perfusion phantom: An efficient and reproducible method to simulate myocardial first‐pass perfusion measurements with cardiovascular magnetic resonance†. Issue 3 (24th April 2012)
- Main Title:
- Perfusion phantom: An efficient and reproducible method to simulate myocardial first‐pass perfusion measurements with cardiovascular magnetic resonance†
- Authors:
- Chiribiri, Amedeo
Schuster, Andreas
Ishida, Masaki
Hautvast, Gilion
Zarinabad, Niloufar
Morton, Geraint
Otton, James
Plein, Sven
Breeuwer, Marcel
Batchelor, Philip
Schaeffter, Tobias
Nagel, Eike - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first‐pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to controlled variations of myocardial perfusion rate, contrast agent dose, and cardiac output. It produced distinct signal intensity curves for perfusion rates ranging from 1 to 10 mL/mL/min. Quantification of myocardial blood flow by signal deconvolution techniques provided accurate measurements of perfusion. The phantom also proved to be very reproducible between different sessions and different operators. This novel hardware perfusion phantom system allows reliable, reproducible, and efficient simulation of myocardial first‐pass MR perfusion. Direct comparison between the results of image‐based quantification and reference values of flow and myocardial perfusion will allow development and validation of accurate quantification methods. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</p> </abstract>
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 3(2013:Mar.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 3(2013:Mar.)
- Issue Display:
- Volume 69, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 3
- Issue Sort Value:
- 2013-0069-0003-0000
- Page Start:
- 698
- Page End:
- 707
- Publication Date:
- 2012-04-24
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24299 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4043.xml