High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 T. Issue 3 (16th May 2012)
- Record Type:
- Journal Article
- Title:
- High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 T. Issue 3 (16th May 2012)
- Main Title:
- High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 T
- Authors:
- Jeong, Ha‐Kyu
Gore, John C.
Anderson, Adam W. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>The combination of parallel imaging with partial Fourier acquisition has greatly improved the performance of diffusion‐weighted single‐shot EPI and is the preferred method for acquisitions at low to medium magnetic field strength such as 1.5 or 3 T. Increased off‐resonance effects and reduced transverse relaxation times at 7 T, however, generate more significant artifacts than at lower magnetic field strength and limit data acquisition. Additional acceleration of k‐space traversal using a multishot approach, which acquires a subset of k‐space data after each excitation, reduces these artifacts relative to conventional single‐shot acquisitions. However, corrections for motion‐induced phase errors are not straightforward in accelerated, diffusion‐weighted multishot EPI because of phase aliasing. In this study, we introduce a simple acquisition and corresponding reconstruction method for diffusion‐weighted multishot EPI with parallel imaging suitable for use at high field. The reconstruction uses a simple modification of the standard sensitivity‐encoding (SENSE) algorithm to account for shot‐to‐shot phase errors; the method is called image reconstruction using image‐space sampling function (IRIS). Using this approach, reconstruction from highly aliased in vivo image data using 2‐D navigator phase information is demonstrated for human diffusion‐weighted imaging studies at 7 T. The final reconstructed images<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>The combination of parallel imaging with partial Fourier acquisition has greatly improved the performance of diffusion‐weighted single‐shot EPI and is the preferred method for acquisitions at low to medium magnetic field strength such as 1.5 or 3 T. Increased off‐resonance effects and reduced transverse relaxation times at 7 T, however, generate more significant artifacts than at lower magnetic field strength and limit data acquisition. Additional acceleration of k‐space traversal using a multishot approach, which acquires a subset of k‐space data after each excitation, reduces these artifacts relative to conventional single‐shot acquisitions. However, corrections for motion‐induced phase errors are not straightforward in accelerated, diffusion‐weighted multishot EPI because of phase aliasing. In this study, we introduce a simple acquisition and corresponding reconstruction method for diffusion‐weighted multishot EPI with parallel imaging suitable for use at high field. The reconstruction uses a simple modification of the standard sensitivity‐encoding (SENSE) algorithm to account for shot‐to‐shot phase errors; the method is called image reconstruction using image‐space sampling function (IRIS). Using this approach, reconstruction from highly aliased in vivo image data using 2‐D navigator phase information is demonstrated for human diffusion‐weighted imaging studies at 7 T. The final reconstructed images show submillimeter in‐plane resolution with no ghosts and much reduced blurring and off‐resonance artifacts. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</p> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 3(2013:Mar.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 3(2013:Mar.)
- Issue Display:
- Volume 69, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 3
- Issue Sort Value:
- 2013-0069-0003-0000
- Page Start:
- 793
- Page End:
- 802
- Publication Date:
- 2012-05-16
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24320 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4043.xml