Optimization strategies for evaluation of brain hemodynamic parameters with qBOLD technique. Issue 4 (23rd May 2012)
- Record Type:
- Journal Article
- Title:
- Optimization strategies for evaluation of brain hemodynamic parameters with qBOLD technique. Issue 4 (23rd May 2012)
- Main Title:
- Optimization strategies for evaluation of brain hemodynamic parameters with qBOLD technique
- Authors:
- Wang, Xiaoqi
Sukstanskii, Alexander L.
Yablonskiy, Dmitriy A. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Quantitative blood oxygenation level dependent technique provides an MRI‐based method to measure tissue hemodynamic parameters such as oxygen extraction fraction and deoxyhemoglobin‐containing (veins and prevenous part of capillaries) cerebral blood volume fraction. It is based on a theory of MR signal dephasing in the presence of blood vessel network and experimental method—gradient echo sampling of spin echo previously proposed and validated on phantoms and animals. In vivo human studies also demonstrated feasibility of this approach but also recognized that obtaining reliable results requires high signal‐to‐noise ratio in the data. In this paper, we analyze in detail the uncertainties of the quantitative blood oxygenation level dependent parameter estimates in the framework of the Bayesian probability theory, namely, we examine how the estimated parameters oxygen extraction fraction and deoxygenated cerebral blood volume fraction depend on their "true values, " signal‐to‐noise ratio, and data sampling strategies. On the basis of this analysis, we develop strategies for optimization of the quantitative blood oxygenation level dependent technique for deoxygenated cerebral blood volume and oxygen extraction fraction evaluation. In particular, it is demonstrated that the use of gradient echo sampling of spin echo sequence allows substantial decrease of measurement errors as the data are<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Quantitative blood oxygenation level dependent technique provides an MRI‐based method to measure tissue hemodynamic parameters such as oxygen extraction fraction and deoxyhemoglobin‐containing (veins and prevenous part of capillaries) cerebral blood volume fraction. It is based on a theory of MR signal dephasing in the presence of blood vessel network and experimental method—gradient echo sampling of spin echo previously proposed and validated on phantoms and animals. In vivo human studies also demonstrated feasibility of this approach but also recognized that obtaining reliable results requires high signal‐to‐noise ratio in the data. In this paper, we analyze in detail the uncertainties of the quantitative blood oxygenation level dependent parameter estimates in the framework of the Bayesian probability theory, namely, we examine how the estimated parameters oxygen extraction fraction and deoxygenated cerebral blood volume fraction depend on their "true values, " signal‐to‐noise ratio, and data sampling strategies. On the basis of this analysis, we develop strategies for optimization of the quantitative blood oxygenation level dependent technique for deoxygenated cerebral blood volume and oxygen extraction fraction evaluation. In particular, it is demonstrated that the use of gradient echo sampling of spin echo sequence allows substantial decrease of measurement errors as the data are acquired on both sides of spin echo. We test our theory on phantom mimicking the structure of blood vessel network. A 3D gradient echo sampling of spin echo pulse sequence is used for the acquisition of the MRI signal that was subsequently analyzed by Bayesian Application Software. The experimental results demonstrated a good agreement with theoretical predictions. Magn Reson Med 69:1034–1043, 2013. © 2012 Wiley Periodicals, Inc.</p> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 4(2013:Apr.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 4(2013:Apr.)
- Issue Display:
- Volume 69, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 4
- Issue Sort Value:
- 2013-0069-0004-0000
- Page Start:
- 1034
- Page End:
- 1043
- Publication Date:
- 2012-05-23
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24338 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3574.xml