Real‐time correction by optical tracking with integrated geometric distortion correction for reducing motion artifacts in functional MRI. Issue 3 (14th May 2012)
- Record Type:
- Journal Article
- Title:
- Real‐time correction by optical tracking with integrated geometric distortion correction for reducing motion artifacts in functional MRI. Issue 3 (14th May 2012)
- Main Title:
- Real‐time correction by optical tracking with integrated geometric distortion correction for reducing motion artifacts in functional MRI
- Authors:
- Rotenberg, David
Chiew, Mark
Ranieri, Shawn
Tam, Fred
Chopra, Rajiv
Graham, Simon J. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>Head motion artifacts are a major problem in functional MRI that limit its use in neuroscience research and clinical settings. Real‐time scan‐plane correction by optical tracking has been shown to correct slice misalignment and nonlinear spin‐history artifacts; however, residual artifacts due to dynamic magnetic field nonuniformity may remain in the data. A recently developed correction technique, Phase Labeling for Additional Coordinate Encoding, can correct for absolute geometric distortion using only the complex image data from two echo planar images with slightly shifted <italic>k</italic>‐space trajectories. An approach is presented that integrates Phase Labeling for Additional Coordinate Encoding into a real‐time scan‐plane update system by optical tracking, applied to a tissue‐equivalent phantom undergoing complex motion and an functional MRI finger tapping experiment with overt head motion to induce dynamic field nonuniformity. Experiments suggest that such integrated volume‐by‐volume corrections are very effective at artifact suppression, with potential to expand functional MRI applications. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</p> </abstract>
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 3(2013:Mar.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 3(2013:Mar.)
- Issue Display:
- Volume 69, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 3
- Issue Sort Value:
- 2013-0069-0003-0000
- Page Start:
- 734
- Page End:
- 748
- Publication Date:
- 2012-05-14
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24309 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4043.xml