Cardiac arterial spin labeling using segmented ECG‐gated Look‐Locker FAIR: Variability and repeatability in preclinical studies. Issue 1 (12th March 2012)
- Record Type:
- Journal Article
- Title:
- Cardiac arterial spin labeling using segmented ECG‐gated Look‐Locker FAIR: Variability and repeatability in preclinical studies. Issue 1 (12th March 2012)
- Main Title:
- Cardiac arterial spin labeling using segmented ECG‐gated Look‐Locker FAIR: Variability and repeatability in preclinical studies
- Authors:
- Campbell‐Washburn, Adrienne E.
Price, Anthony N.
Wells, Jack A.
Thomas, David L.
Ordidge, Roger J.
Lythgoe, Mark F. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>MRI is important for the assessment of cardiac structure and function in preclinical studies of cardiac disease. Arterial spin labeling techniques can be used to measure perfusion noninvasively. In this study, an electrocardiogram‐gated Look‐Locker sequence with segmented <italic>k</italic>‐space acquisition has been implemented to acquire single slice arterial spin labeling data sets in 15 min in the mouse heart. A data logger was introduced to improve data quality by: (1) allowing automated rejection of respiration‐corrupted images, (2) providing additional prospective gating to improve consistency of acquisition timing, and (3) allowing the recombination of uncorrupted <italic>k</italic>‐space lines from consecutive data sets to reduce respiration corruption. Finally, variability and repeatability of perfusion estimation within‐session, between‐session, between‐animal, and between image rejection criteria were assessed in mice. The criterion used to reject images from the <italic>T</italic><sub>1</sub> fit was shown to affect the perfusion estimation. These data showed that the between‐animal coefficient of variability (24%) was greater than the between‐session variability (17%) and within‐session variability (11%). Furthermore, the magnitude of change in perfusion required to detect differences was 30% (within‐session) and 55% (between‐session) according to Bland‐Altman repeatability analysis. These<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>MRI is important for the assessment of cardiac structure and function in preclinical studies of cardiac disease. Arterial spin labeling techniques can be used to measure perfusion noninvasively. In this study, an electrocardiogram‐gated Look‐Locker sequence with segmented <italic>k</italic>‐space acquisition has been implemented to acquire single slice arterial spin labeling data sets in 15 min in the mouse heart. A data logger was introduced to improve data quality by: (1) allowing automated rejection of respiration‐corrupted images, (2) providing additional prospective gating to improve consistency of acquisition timing, and (3) allowing the recombination of uncorrupted <italic>k</italic>‐space lines from consecutive data sets to reduce respiration corruption. Finally, variability and repeatability of perfusion estimation within‐session, between‐session, between‐animal, and between image rejection criteria were assessed in mice. The criterion used to reject images from the <italic>T</italic><sub>1</sub> fit was shown to affect the perfusion estimation. These data showed that the between‐animal coefficient of variability (24%) was greater than the between‐session variability (17%) and within‐session variability (11%). Furthermore, the magnitude of change in perfusion required to detect differences was 30% (within‐session) and 55% (between‐session) according to Bland‐Altman repeatability analysis. These technique developments and repeatability statistics will provide a platform for future preclinical studies applying cardiac arterial spin labeling. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</p> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 1(2013:Jan.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 1(2013:Jan.)
- Issue Display:
- Volume 69, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 1
- Issue Sort Value:
- 2013-0069-0001-0000
- Page Start:
- 238
- Page End:
- 247
- Publication Date:
- 2012-03-12
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24243 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4335.xml