An 11‐channel radio frequency phased array coil for magnetic resonance guided high‐intensity focused ultrasound of the breast. Issue 1 (16th March 2012)
- Record Type:
- Journal Article
- Title:
- An 11‐channel radio frequency phased array coil for magnetic resonance guided high‐intensity focused ultrasound of the breast. Issue 1 (16th March 2012)
- Main Title:
- An 11‐channel radio frequency phased array coil for magnetic resonance guided high‐intensity focused ultrasound of the breast
- Authors:
- Minalga, E.
Payne, A.
Merrill, R.
Todd, N.
Vijayakumar, S.
Kholmovski, E.
Parker, D. L.
Hadley, J. R. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>In this study, a radio frequency phased array coil was built to image the breast in conjunction with a magnetic resonance guided high‐intensity focused ultrasound (MRgHIFU) device designed specifically to treat the breast in a treatment cylinder with reduced water volume. The MRgHIFU breast coil was comprised of a 10‐channel phased array coil placed around an MRgHIFU treatment cylinder where nearest‐neighbor decoupling was achieved with capacitive decoupling in a shared leg. In addition a single loop coil was placed at the chest wall making a total of 11 channels. The radio frequency coil array design presented in this work was chosen based on ease of implementation, increased visualization into the treatment cylinder, image reconstruction speed, temporal resolution, and resulting signal‐to‐noise ratio profiles. This work presents a dedicated 11‐channel coil for imaging of the breast tissue in the MRgHIFU setup without obstruction of the ultrasound beam and, specifically, compares its performance in signal‐to‐noise, overall imaging time, and temperature measurement accuracy to that of the standard single chest‐loop coil typically used in breast MRgHIFU. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</p> </abstract>
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 1(2013:Jan.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 1(2013:Jan.)
- Issue Display:
- Volume 69, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 1
- Issue Sort Value:
- 2013-0069-0001-0000
- Page Start:
- 295
- Page End:
- 302
- Publication Date:
- 2012-03-16
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24247 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4335.xml