Feasibility of shutter‐speed DCE‐MRI for improved prostate cancer detection. Issue 1 (27th March 2012)
- Record Type:
- Journal Article
- Title:
- Feasibility of shutter‐speed DCE‐MRI for improved prostate cancer detection. Issue 1 (27th March 2012)
- Main Title:
- Feasibility of shutter‐speed DCE‐MRI for improved prostate cancer detection
- Authors:
- Li, Xin
Priest, Ryan A.
Woodward, William J.
Tagge, Ian J.
Siddiqui, Faisal
Huang, Wei
Rooney, William D.
Beer, Tomasz M.
Garzotto, Mark G.
Springer, Charles S. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>The feasibility of shutter‐speed model dynamic‐contrast‐enhanced MRI pharmacokinetic analyses for prostate cancer detection was investigated in a prebiopsy patient cohort. Differences of results from the fast‐exchange‐regime‐allowed (FXR‐a) shutter‐speed model version and the fast‐exchange‐limit‐constrained (FXL‐c) standard model are demonstrated. Although the spatial information is more limited, postdynamic‐contrast‐enhanced MRI biopsy specimens were also examined. The MRI results were correlated with the biopsy pathology findings. Of all the model parameters, region‐of‐interest‐averaged <italic>K</italic><sup>trans</sup> difference [Δ<italic>K</italic><sup>trans</sup> ≡ <italic>K</italic><sup>trans</sup>(FXR‐a) − <italic>K</italic><sup>trans</sup>(FXL‐c)] or two‐dimensional <italic>K</italic><sup>trans</sup>(FXR‐a) vs. <italic>k</italic><sub>ep</sub>(FXR‐a) values were found to provide the most useful biomarkers for malignant/benign prostate tissue discrimination (at 100% sensitivity for a population of 13, the specificity is 88%) and disease burden determination. (The best specificity for the fast‐exchange‐limit‐constrained analysis is 63%, with the two‐dimensional plot.) <italic>K</italic><sup>trans</sup> and <italic>k</italic><sub>ep</sub> are each measures of passive transcapillary contrast reagent transfer rate constants. Parameter value increases with shutter‐speed model (relative to standard<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>The feasibility of shutter‐speed model dynamic‐contrast‐enhanced MRI pharmacokinetic analyses for prostate cancer detection was investigated in a prebiopsy patient cohort. Differences of results from the fast‐exchange‐regime‐allowed (FXR‐a) shutter‐speed model version and the fast‐exchange‐limit‐constrained (FXL‐c) standard model are demonstrated. Although the spatial information is more limited, postdynamic‐contrast‐enhanced MRI biopsy specimens were also examined. The MRI results were correlated with the biopsy pathology findings. Of all the model parameters, region‐of‐interest‐averaged <italic>K</italic><sup>trans</sup> difference [Δ<italic>K</italic><sup>trans</sup> ≡ <italic>K</italic><sup>trans</sup>(FXR‐a) − <italic>K</italic><sup>trans</sup>(FXL‐c)] or two‐dimensional <italic>K</italic><sup>trans</sup>(FXR‐a) vs. <italic>k</italic><sub>ep</sub>(FXR‐a) values were found to provide the most useful biomarkers for malignant/benign prostate tissue discrimination (at 100% sensitivity for a population of 13, the specificity is 88%) and disease burden determination. (The best specificity for the fast‐exchange‐limit‐constrained analysis is 63%, with the two‐dimensional plot.) <italic>K</italic><sup>trans</sup> and <italic>k</italic><sub>ep</sub> are each measures of passive transcapillary contrast reagent transfer rate constants. Parameter value increases with shutter‐speed model (relative to standard model) analysis are larger in malignant foci than in normal‐appearing glandular tissue. Pathology analyses verify the shutter‐speed model (FXR‐a) promise for prostate cancer detection. Parametric mapping may further improve pharmacokinetic biomarker performance. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</p> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 69:Issue 1(2013:Jan.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 69:Issue 1(2013:Jan.)
- Issue Display:
- Volume 69, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 69
- Issue:
- 1
- Issue Sort Value:
- 2013-0069-0001-0000
- Page Start:
- 171
- Page End:
- 178
- Publication Date:
- 2012-03-27
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24211 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4335.xml