Development and validation studies for determination of phenylpropanoid‐substituted flavan‐3‐ols in semipurified extract of Trichilia catigua by high‐performance liquid chromatography with photodiode array detection. Issue 7 (10th April 2013)
- Record Type:
- Journal Article
- Title:
- Development and validation studies for determination of phenylpropanoid‐substituted flavan‐3‐ols in semipurified extract of Trichilia catigua by high‐performance liquid chromatography with photodiode array detection. Issue 7 (10th April 2013)
- Main Title:
- Development and validation studies for determination of phenylpropanoid‐substituted flavan‐3‐ols in semipurified extract of Trichilia catigua by high‐performance liquid chromatography with photodiode array detection
- Authors:
- Longhini, Renata
Klein, Traudi
Luciano Bruschi, Marcos
da, Waldir Veríssimo
Rodrigues, Juliana
Lopes, Norberto Peporine
de, João Carlos Palazzo - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>The phenolic compounds are the main phytochemical constituents of the bark of <italic>Trichilia catigua</italic> and are commonly used for medicinal purposes. An HPLC method for the simultaneous quantification of phenolic compounds (procyanidin B2 (PB2), epicatechin (EPC), chinchonains Ia, Ib, IIa, IIb, catechin, and chrologenic acid) in <italic>T. catigua</italic> extract was developed and validated. A suitable chromatographic system was selected, which uses a gradient elution with methanol/ACN (75:25), and water both with 0.05% TFA, as mobile phase, column Luna, 280 nm, and flow 0.4 mL/min. Validation of the analytical method was based on the parameters: linearity, precision, LODs and LOQs, accuracy, robustness, and stability. The method showed linearity for PB2 and EPC, in the range 10–120 μg/mL with good correlation coefficients (>0.996). For precision, the repeatability ranged from 1.89 to 3.23%, and the values for accuracy for PB2 and EPC were 95 and 89%, respectively. The LODs and LOQs for PB2 were 1.36 and 4.12 μg/mL, and for EPC were 2.18 and 6.61 μg/mL, respectively. The method was robust under the conditions employed. The proposed method could be employed for quality assessment of <italic>T. catigua</italic>, as well as pharmaceutical products.</p> </abstract>
- Is Part Of:
- Journal of separation science. Volume 36:Issue 7(2013:Apr.)
- Journal:
- Journal of separation science
- Issue:
- Volume 36:Issue 7(2013:Apr.)
- Issue Display:
- Volume 36, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 36
- Issue:
- 7
- Issue Sort Value:
- 2013-0036-0007-0000
- Page Start:
- 1247
- Page End:
- 1254
- Publication Date:
- 2013-04-10
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201200911 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4064.xml