Comparison of 3‐point dixon imaging and fuzzy C‐means clustering methods for breast density measurement. Issue 2 (4th January 2013)
- Record Type:
- Journal Article
- Title:
- Comparison of 3‐point dixon imaging and fuzzy C‐means clustering methods for breast density measurement. Issue 2 (4th January 2013)
- Main Title:
- Comparison of 3‐point dixon imaging and fuzzy C‐means clustering methods for breast density measurement
- Authors:
- Clendenen, Tess V.
Zeleniuch‐Jacquotte, Anne
Moy, Linda
Pike, Malcolm C.
Rusinek, Henry
Kim, Sungheon - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24002-sec-0001" sec-type="section"> <title>Purpose</title> <p>To assess two methods of fat and fibroglandular tissue (FGT) segmentation for measuring breast MRI FGT volume and FGT%, the volume percentage of FGT in the breast, in longitudinal studies.</p> </sec> <sec id="jmri24002-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Nine premenopausal women provided one MRI per week for 4 weeks during a natural menstrual cycle for a total of 36 datasets. We compared a fuzzy c‐means (FC) and a 3‐point Dixon segmentation method for estimation of changes in FGT volume and FGT% across the menstrual cycle. We also assessed whether differences due to changes in positioning each week could be minimized by coregistration, i.e., the application of the breast boundary selected at one visit to images obtained at other visits.</p> </sec> <sec id="jmri24002-sec-0003" sec-type="section"> <title>Results</title> <p>FC and Dixon FGT volume were highly correlated (r = 0.93, <italic>P</italic> &lt; 0.001), as was FC and Dixon FGT% (r = 0.86, <italic>P</italic> = 0.01), although Dixon measurements were on average 10–20% higher. Although FGT measured by both methods showed the expected pattern of increase during the menstrual cycle, the magnitude, and for one woman the direction, of change varied according to the method used. Measurements of FGT for coregistered images were in close<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24002-sec-0001" sec-type="section"> <title>Purpose</title> <p>To assess two methods of fat and fibroglandular tissue (FGT) segmentation for measuring breast MRI FGT volume and FGT%, the volume percentage of FGT in the breast, in longitudinal studies.</p> </sec> <sec id="jmri24002-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Nine premenopausal women provided one MRI per week for 4 weeks during a natural menstrual cycle for a total of 36 datasets. We compared a fuzzy c‐means (FC) and a 3‐point Dixon segmentation method for estimation of changes in FGT volume and FGT% across the menstrual cycle. We also assessed whether differences due to changes in positioning each week could be minimized by coregistration, i.e., the application of the breast boundary selected at one visit to images obtained at other visits.</p> </sec> <sec id="jmri24002-sec-0003" sec-type="section"> <title>Results</title> <p>FC and Dixon FGT volume were highly correlated (r = 0.93, <italic>P</italic> &lt; 0.001), as was FC and Dixon FGT% (r = 0.86, <italic>P</italic> = 0.01), although Dixon measurements were on average 10–20% higher. Although FGT measured by both methods showed the expected pattern of increase during the menstrual cycle, the magnitude, and for one woman the direction, of change varied according to the method used. Measurements of FGT for coregistered images were in close agreement with those for which the boundaries were determined independently.</p> </sec> <sec id="jmri24002-sec-0004" sec-type="section"> <title>Conclusion</title> <p>The method of segmentation of fat and FGT tissue may have an impact on the results of longitudinal studies of changes in breast MRI FGT. J. Magn. Reson. Imaging 2013;38:474–481. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 38:Issue 2(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 38:Issue 2(2013)
- Issue Display:
- Volume 38, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 2
- Issue Sort Value:
- 2013-0038-0002-0000
- Page Start:
- 474
- Page End:
- 481
- Publication Date:
- 2013-01-04
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24002 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3003.xml