Inter‐ and intra‐rater reliability of blood and cerebrospinal fluid flow quantification by phase‐contrast MRI. Issue 3 (31st January 2013)
- Record Type:
- Journal Article
- Title:
- Inter‐ and intra‐rater reliability of blood and cerebrospinal fluid flow quantification by phase‐contrast MRI. Issue 3 (31st January 2013)
- Main Title:
- Inter‐ and intra‐rater reliability of blood and cerebrospinal fluid flow quantification by phase‐contrast MRI
- Authors:
- Koerte, Inga
Haberl, Caroline
Schmidt, Michael
Pomschar, Andreas
Lee, Sang
Rapp, Petra
Steffinger, Denise
Tain, Rong‐Wen
Alperin, Noam
Ertl‐Wagner, Birgit - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24013-sec-0001" sec-type="section"> <title>Purpose:</title> <p>To evaluate the intra‐ and inter‐rater reliability of the quantification of blood and CSF flow rates by phase contrast MRI.</p> </sec> <sec id="jmri24013-sec-0002" sec-type="section"> <title>Materials and Methods:</title> <p>Blood and CSF flows in the upper cervical region were imaged with velocity‐encoded cine‐phase contrast using 3T scanners from different manufacturers at two centers. Data of 6 subjects scanned in center A and of 5 subjects in center B were analyzed by six readers at two levels of training. Each data set was analyzed three times in a randomized order for a total of 33 data sets. Intra‐class correlation coefficients (ICC) were calculated for the primary measurements of areas and flow rates through the main cervical arteries, veins and the CSF space, and for secondary parameters derived from the individual flow rates.</p> </sec> <sec id="jmri24013-sec-0003" sec-type="section"> <title>Results:</title> <p>ICC ranged from 0.80 to 0.96 for the lumen area and from 0.97 to 0.99 for the volumetric flow rate. The ICC for the derived secondary measures ranged from 0.85 to 0.99. Differences due to operator level of training were not statistically significant.</p> </sec> <sec id="jmri24013-sec-0004" sec-type="section"> <title>Conclusion:</title> <p>High intra‐ and inter‐rater reliability of volumetric flow<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24013-sec-0001" sec-type="section"> <title>Purpose:</title> <p>To evaluate the intra‐ and inter‐rater reliability of the quantification of blood and CSF flow rates by phase contrast MRI.</p> </sec> <sec id="jmri24013-sec-0002" sec-type="section"> <title>Materials and Methods:</title> <p>Blood and CSF flows in the upper cervical region were imaged with velocity‐encoded cine‐phase contrast using 3T scanners from different manufacturers at two centers. Data of 6 subjects scanned in center A and of 5 subjects in center B were analyzed by six readers at two levels of training. Each data set was analyzed three times in a randomized order for a total of 33 data sets. Intra‐class correlation coefficients (ICC) were calculated for the primary measurements of areas and flow rates through the main cervical arteries, veins and the CSF space, and for secondary parameters derived from the individual flow rates.</p> </sec> <sec id="jmri24013-sec-0003" sec-type="section"> <title>Results:</title> <p>ICC ranged from 0.80 to 0.96 for the lumen area and from 0.97 to 0.99 for the volumetric flow rate. The ICC for the derived secondary measures ranged from 0.85 to 0.99. Differences due to operator level of training were not statistically significant.</p> </sec> <sec id="jmri24013-sec-0004" sec-type="section"> <title>Conclusion:</title> <p>High intra‐ and inter‐rater reliability of volumetric flow rate measurements is currently achievable across manufacturers and users' skill levels with a pulsatility based automated lumen segmentation. <bold>J. Magn. Reson. Imaging 2013;38:655–662. © 2013 Wiley Periodicals, Inc.</bold></p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 38:Issue 3(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 38:Issue 3(2013)
- Issue Display:
- Volume 38, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 3
- Issue Sort Value:
- 2013-0038-0003-0000
- Page Start:
- 655
- Page End:
- 662
- Publication Date:
- 2013-01-31
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24013 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3018.xml