Effects of perfusion on diffusion changes in human brain tumors. Issue 4 (6th February 2013)
- Record Type:
- Journal Article
- Title:
- Effects of perfusion on diffusion changes in human brain tumors. Issue 4 (6th February 2013)
- Main Title:
- Effects of perfusion on diffusion changes in human brain tumors
- Authors:
- Cohen, Alexander D.
LaViolette, Peter S.
Prah, Melissa
Connelly, Jennifer
Malkin, Mark G.
Rand, Scott D.
Mueller, Wade M.
Schmainda, Kathleen M. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24042-sec-0001" sec-type="section"> <title>Purpose</title> <p>To characterize the influence of perfusion on the measurement of diffusion changes over time when ADC is computed using standard two‐point methods.</p> </sec> <sec id="jmri24042-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Functional diffusion maps (FDMs), which depict changes in diffusion over time, were compared with rCBV changes in patients with brain tumors. The FDMs were created by coregistering and subtracting ADC maps from two time points and categorizing voxels where ADC significantly increased (iADC), decreased (dADC), or did not change (ncADC). Traditional FDMs (tFDMs) were computed using b = 0, 1000 s/mm<sup>2</sup>. Flow‐compensated FDMs (fcFDMs) were calculated using b = 500, 1000 s/mm<sup>2</sup>. Perfusion's influence on FDMs was determined by evaluating changes in rCBV in areas where the ADC change significantly differed between the two FDMs.</p> </sec> <sec id="jmri24042-sec-0003" sec-type="section"> <title>Results</title> <p>The mean ΔrCBV in voxels that changed from iADC (dADC) on the tFDM to ncADC on the fcFDM was significantly greater (less) than zero. In addition, mean ΔrCBV in iADC (dADC) voxels on the tFDM was significantly higher (lower) than in iADC (dADC) voxels on the fcFDM.</p> </sec> <sec id="jmri24042-sec-0004" sec-type="section"> <title>Conclusion</title><abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24042-sec-0001" sec-type="section"> <title>Purpose</title> <p>To characterize the influence of perfusion on the measurement of diffusion changes over time when ADC is computed using standard two‐point methods.</p> </sec> <sec id="jmri24042-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Functional diffusion maps (FDMs), which depict changes in diffusion over time, were compared with rCBV changes in patients with brain tumors. The FDMs were created by coregistering and subtracting ADC maps from two time points and categorizing voxels where ADC significantly increased (iADC), decreased (dADC), or did not change (ncADC). Traditional FDMs (tFDMs) were computed using b = 0, 1000 s/mm<sup>2</sup>. Flow‐compensated FDMs (fcFDMs) were calculated using b = 500, 1000 s/mm<sup>2</sup>. Perfusion's influence on FDMs was determined by evaluating changes in rCBV in areas where the ADC change significantly differed between the two FDMs.</p> </sec> <sec id="jmri24042-sec-0003" sec-type="section"> <title>Results</title> <p>The mean ΔrCBV in voxels that changed from iADC (dADC) on the tFDM to ncADC on the fcFDM was significantly greater (less) than zero. In addition, mean ΔrCBV in iADC (dADC) voxels on the tFDM was significantly higher (lower) than in iADC (dADC) voxels on the fcFDM.</p> </sec> <sec id="jmri24042-sec-0004" sec-type="section"> <title>Conclusion</title> <p>The ability to accurately identify changes in diffusion on traditional FDMs is confounded in areas where perfusion and diffusion changes are colocalized. Flow‐compensated FDMs, which use only non‐zero b‐values, should therefore be the standard approach. J. Magn. Reson. Imaging 2013;38:868–875. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 38:Issue 4(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 38:Issue 4(2013)
- Issue Display:
- Volume 38, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 4
- Issue Sort Value:
- 2013-0038-0004-0000
- Page Start:
- 868
- Page End:
- 875
- Publication Date:
- 2013-02-06
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24042 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3757.xml