Improved correction for gradient nonlinearity effects in diffusion‐weighted imaging. Issue 2 (21st November 2012)
- Record Type:
- Journal Article
- Title:
- Improved correction for gradient nonlinearity effects in diffusion‐weighted imaging. Issue 2 (21st November 2012)
- Main Title:
- Improved correction for gradient nonlinearity effects in diffusion‐weighted imaging
- Authors:
- Tan, Ek T.
Marinelli, Luca
Slavens, Zachary W.
King, Kevin F.
Hardy, Christopher J. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri23942-sec-0001" sec-type="section"> <title>Purpose</title> <p>To provide an improved correction for gradient nonlinearity (GN) effects in diffusion‐weighted imaging (DWI). These effects produce spatially varying apparent diffusion coefficient (ADC), a result that will be significant in large field‐of‐view imaging, and may be confounded by distortion and concomitant fields related to the DWI acquisition.</p> </sec> <sec id="jmri23942-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>The effect of more accurate gradient field maps on GN correction (GNC) of ADC was evaluated. A simulation compared GN effects in commonly imaged anatomy. A temperature‐controlled phantom was imaged at positions 0 cm and 11 cm from isocenter and in two whole‐body MRI systems at 1.5T with different patient bore diameters (55 cm and 60 cm). Varying correction methods were applied to determine the errors from spatial variance and interscanner reproducibility.</p> </sec> <sec id="jmri23942-sec-0003" sec-type="section"> <title>Results</title> <p>As compared to conventional fifth‐order spherical harmonics, a seventh‐order GNC improved ADC accuracy by 1%. The combination of GNC with a dual‐spin‐echo pulse sequence and a retrospective concomitant field correction reduced ADC error due to spatial variance from 9.5% to 1.8% (55 cm bore) and from 4.2% to 1.8% (60 cm bore). The error in ADC<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri23942-sec-0001" sec-type="section"> <title>Purpose</title> <p>To provide an improved correction for gradient nonlinearity (GN) effects in diffusion‐weighted imaging (DWI). These effects produce spatially varying apparent diffusion coefficient (ADC), a result that will be significant in large field‐of‐view imaging, and may be confounded by distortion and concomitant fields related to the DWI acquisition.</p> </sec> <sec id="jmri23942-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>The effect of more accurate gradient field maps on GN correction (GNC) of ADC was evaluated. A simulation compared GN effects in commonly imaged anatomy. A temperature‐controlled phantom was imaged at positions 0 cm and 11 cm from isocenter and in two whole‐body MRI systems at 1.5T with different patient bore diameters (55 cm and 60 cm). Varying correction methods were applied to determine the errors from spatial variance and interscanner reproducibility.</p> </sec> <sec id="jmri23942-sec-0003" sec-type="section"> <title>Results</title> <p>As compared to conventional fifth‐order spherical harmonics, a seventh‐order GNC improved ADC accuracy by 1%. The combination of GNC with a dual‐spin‐echo pulse sequence and a retrospective concomitant field correction reduced ADC error due to spatial variance from 9.5% to 1.8% (55 cm bore) and from 4.2% to 1.8% (60 cm bore). The error in ADC attributed to interscanner reproducibility was reduced from 5.8% to 0.15% (at isocenter) and from 10% to 0.63% (11 cm from isocenter).</p> </sec> <sec id="jmri23942-sec-0004" sec-type="section"> <title>Conclusion</title> <p>GNC in DWI improved spatial accuracy and interscanner reproducibility of ADC. J. Magn. Reson. Imaging 2013;38:448–453. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 38:Issue 2(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 38:Issue 2(2013)
- Issue Display:
- Volume 38, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 2
- Issue Sort Value:
- 2013-0038-0002-0000
- Page Start:
- 448
- Page End:
- 453
- Publication Date:
- 2012-11-21
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23942 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3003.xml