Optimizing cine MRI for uterine peristalsis: A comparison of three different single shot fast spin echo techniques. Issue 1 (29th November 2012)
- Record Type:
- Journal Article
- Title:
- Optimizing cine MRI for uterine peristalsis: A comparison of three different single shot fast spin echo techniques. Issue 1 (29th November 2012)
- Main Title:
- Optimizing cine MRI for uterine peristalsis: A comparison of three different single shot fast spin echo techniques
- Authors:
- Nakai, Asako
Reinhold, Caroline
Noel, Patricia
Kido, Aki
Rafatzand, Khashayar
Ito, Isao
Togashi, Kaori - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri23946-sec-0001" sec-type="section"> <title>Purpose</title> <p>To determine the optimal single shot fast spin echo (SSFSE) technique by varying interval between image acquisitions for cine MRI of uterine peristalsis.</p> </sec> <sec id="jmri23946-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>MRI was performed in 13 premenopausal women (4 normal and 9 with benign pelvic pathology) in various phases of their menstrual cycle. Midsagittal uterus was scanned using a multiphasic SSFSE technique at 2‐, 3‐, and 4‐s intervals over 2 min. Three readers independently and randomly evaluated for peristaltic frequency/2 min, longitudinal direction and intensity of peristalsis in three imaging parameters. Contrast‐to‐noise ratios (CNRs) were also obtained.</p> </sec> <sec id="jmri23946-sec-0003" sec-type="section"> <title>Results</title> <p>Peristaltic frequency for the 2, 3, and 4 s was 2.2 ± 2.3, 3.3 ± 1.5, and 3.6 ± 1.3 waves/2 min, respectively. It increased by 1.5 (95% confidence interval [CI]: 0.31–2.64) waves/2 min with 4 s compared with 2 s. Direction was detected for the 2, 3, and 4 s in 5/13(38%), 9/13(69%) and 12/13(92%) women. Compared with 2 s, intensity of peristalsis in endometrial movement (<italic>P</italic> = 0.04), signal change of the JZ (<italic>P</italic> = 0.03), and spread into outer myometrium (<italic>P</italic> = 0.02),<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri23946-sec-0001" sec-type="section"> <title>Purpose</title> <p>To determine the optimal single shot fast spin echo (SSFSE) technique by varying interval between image acquisitions for cine MRI of uterine peristalsis.</p> </sec> <sec id="jmri23946-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>MRI was performed in 13 premenopausal women (4 normal and 9 with benign pelvic pathology) in various phases of their menstrual cycle. Midsagittal uterus was scanned using a multiphasic SSFSE technique at 2‐, 3‐, and 4‐s intervals over 2 min. Three readers independently and randomly evaluated for peristaltic frequency/2 min, longitudinal direction and intensity of peristalsis in three imaging parameters. Contrast‐to‐noise ratios (CNRs) were also obtained.</p> </sec> <sec id="jmri23946-sec-0003" sec-type="section"> <title>Results</title> <p>Peristaltic frequency for the 2, 3, and 4 s was 2.2 ± 2.3, 3.3 ± 1.5, and 3.6 ± 1.3 waves/2 min, respectively. It increased by 1.5 (95% confidence interval [CI]: 0.31–2.64) waves/2 min with 4 s compared with 2 s. Direction was detected for the 2, 3, and 4 s in 5/13(38%), 9/13(69%) and 12/13(92%) women. Compared with 2 s, intensity of peristalsis in endometrial movement (<italic>P</italic> = 0.04), signal change of the JZ (<italic>P</italic> = 0.03), and spread into outer myometrium (<italic>P</italic> = 0.02), CNR<sub>endometrium‐JZ</sub> by 57% (<italic>P</italic> &lt; 0.001), and CNR<sub>outer myometrium‐JZ</sub> by 45% (<italic>P</italic> &lt; 0.01) increased with 4 s.</p> </sec> <sec id="jmri23946-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Cine MRI with SSFSE sequence for uterine peristaltism is best performed using a 4‐s scan interval. J. Magn. Reson. Imaging 2013;38:161–167. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 38:Issue 1(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 38:Issue 1(2013)
- Issue Display:
- Volume 38, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2013-0038-0001-0000
- Page Start:
- 161
- Page End:
- 167
- Publication Date:
- 2012-11-29
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23946 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3755.xml