Use of 3T MRI and an unspoiled 3D fast gradient echo sequence for porcine knee cartilage volumetry: Preliminary findings. Issue 1 (2nd November 2012)
- Record Type:
- Journal Article
- Title:
- Use of 3T MRI and an unspoiled 3D fast gradient echo sequence for porcine knee cartilage volumetry: Preliminary findings. Issue 1 (2nd November 2012)
- Main Title:
- Use of 3T MRI and an unspoiled 3D fast gradient echo sequence for porcine knee cartilage volumetry: Preliminary findings
- Authors:
- Cromer, Megan S.
Foster, Sheryl L.
Bourne, Roger M.
Fransen, Marlene
Fulton, Roger
Wang, Shih‐Chang - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri23898-sec-0001" sec-type="section"> <title>Purpose</title> <p>To assess the utility of knee cartilage volumetry using an unspoiled fat‐suppressed 3D fast gradient echo (FGRE) sequence at 3T.</p> </sec> <sec id="jmri23898-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Sagittal magnetic resonance (MR) images were obtained with an unspoiled fat‐suppressed 3D FGRE sequence in eight porcine knees. Manual segmentation was used to derive the cartilage volume. This volume was compared to a volume measurement of cartilage scraping specimens obtained by water displacement. Imaging was repeated five times in four of the knees to assess interscan volume measurement reproducibility and calculate precision error. A single 3D dataset was manually segmented five times at weekly intervals to assess intraobserver volume measurement reproducibility.</p> </sec> <sec id="jmri23898-sec-0003" sec-type="section"> <title>Results</title> <p>Total cartilage volume obtained from MRI and water displacement correlated well (<italic>r</italic> = 0.75). The interscan reproducibility of total volume measurements, expressed as the coefficient of variation (CV), was 4.2%, and the precision error (root mean square [RMS] CV) was 4.1%. The CV of intraobserver estimates of total cartilage volume by MRI was 3.6%.</p> </sec> <sec id="jmri23898-sec-0004" sec-type="section"><abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri23898-sec-0001" sec-type="section"> <title>Purpose</title> <p>To assess the utility of knee cartilage volumetry using an unspoiled fat‐suppressed 3D fast gradient echo (FGRE) sequence at 3T.</p> </sec> <sec id="jmri23898-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>Sagittal magnetic resonance (MR) images were obtained with an unspoiled fat‐suppressed 3D FGRE sequence in eight porcine knees. Manual segmentation was used to derive the cartilage volume. This volume was compared to a volume measurement of cartilage scraping specimens obtained by water displacement. Imaging was repeated five times in four of the knees to assess interscan volume measurement reproducibility and calculate precision error. A single 3D dataset was manually segmented five times at weekly intervals to assess intraobserver volume measurement reproducibility.</p> </sec> <sec id="jmri23898-sec-0003" sec-type="section"> <title>Results</title> <p>Total cartilage volume obtained from MRI and water displacement correlated well (<italic>r</italic> = 0.75). The interscan reproducibility of total volume measurements, expressed as the coefficient of variation (CV), was 4.2%, and the precision error (root mean square [RMS] CV) was 4.1%. The CV of intraobserver estimates of total cartilage volume by MRI was 3.6%.</p> </sec> <sec id="jmri23898-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Interscan reproducibility of quantification of total cartilage volume and reproducibility of the manual segmentation technique were both high (&gt;95%). Accurate and reproducible cartilage volumetry can be obtained by using a clinical unspoiled fat‐suppressed 3D FGRE acquired at 3T MRI. J. Magn. Reson. Imaging 2013;38:245–250. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 38:Issue 1(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 38:Issue 1(2013)
- Issue Display:
- Volume 38, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2013-0038-0001-0000
- Page Start:
- 245
- Page End:
- 250
- Publication Date:
- 2012-11-02
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23898 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3756.xml