Venous and arterial flow quantification are equally accurate and precise with parallel imaging compressed sensing 4D phase contrast MRI. Issue 6 (21st November 2012)
- Record Type:
- Journal Article
- Title:
- Venous and arterial flow quantification are equally accurate and precise with parallel imaging compressed sensing 4D phase contrast MRI. Issue 6 (21st November 2012)
- Main Title:
- Venous and arterial flow quantification are equally accurate and precise with parallel imaging compressed sensing 4D phase contrast MRI
- Authors:
- Tariq, Umar
Hsiao, Albert
Alley, Marcus
Zhang, Tao
Lustig, Michael
Vasanawala, Shreyas S. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To evaluate the precision and accuracy of parallel‐imaging compressed‐sensing 4D phase contrast (PICS‐4DPC) magnetic resonance imaging (MRI) venous flow quantification in children with patients referred for cardiac MRI at our children's hospital.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>With Institutional Review Board (IRB) approval and Health Insurance Portability and Accountability Act (HIPAA) compliance, 22 consecutive patients without shunts underwent 4DPC as part of clinical cardiac MRI examinations. Flow measurements were obtained in the superior and inferior vena cava, ascending and descending aorta, and the pulmonary trunk. Conservation of flow to the upper, lower, and whole body was used as an internal physiologic control. The arterial and venous flow rates at each location were compared with paired <italic>t</italic>‐tests and F‐tests to assess relative accuracy and precision.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>Arterial and venous flow measurements were strongly correlated with the upper (ρ = 0.89), lower (ρ = 0.96), and whole body (ρ = 0.97); net aortic and pulmonary trunk flow rates were also tightly correlated (ρ = 0.97). There was no significant difference in the value or precision of arterial and venous flow measurements in upper, lower, or<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To evaluate the precision and accuracy of parallel‐imaging compressed‐sensing 4D phase contrast (PICS‐4DPC) magnetic resonance imaging (MRI) venous flow quantification in children with patients referred for cardiac MRI at our children's hospital.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>With Institutional Review Board (IRB) approval and Health Insurance Portability and Accountability Act (HIPAA) compliance, 22 consecutive patients without shunts underwent 4DPC as part of clinical cardiac MRI examinations. Flow measurements were obtained in the superior and inferior vena cava, ascending and descending aorta, and the pulmonary trunk. Conservation of flow to the upper, lower, and whole body was used as an internal physiologic control. The arterial and venous flow rates at each location were compared with paired <italic>t</italic>‐tests and F‐tests to assess relative accuracy and precision.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>Arterial and venous flow measurements were strongly correlated with the upper (ρ = 0.89), lower (ρ = 0.96), and whole body (ρ = 0.97); net aortic and pulmonary trunk flow rates were also tightly correlated (ρ = 0.97). There was no significant difference in the value or precision of arterial and venous flow measurements in upper, lower, or whole body, although there was a trend toward improved precision with lower velocity‐encoding settings.</p> </sec> <sec id="abs1-4" sec-type="section"> <title>Conclusion:</title> <p>With PICS‐4DPC MRI, the accuracy and precision of venous flow quantification are comparable to that of arterial flow quantification at velocity‐encodings appropriate for arterial vessels. J. Magn. Reson. Imaging 2013;37:1419–1426. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 37:Issue 6(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 37:Issue 6(2013)
- Issue Display:
- Volume 37, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 37
- Issue:
- 6
- Issue Sort Value:
- 2013-0037-0006-0000
- Page Start:
- 1419
- Page End:
- 1426
- Publication Date:
- 2012-11-21
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23936 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3276.xml