Reproducibility of rapid short echo time CSI at 3 tesla for clinical applications. Issue 2 (25th September 2012)
- Record Type:
- Journal Article
- Title:
- Reproducibility of rapid short echo time CSI at 3 tesla for clinical applications. Issue 2 (25th September 2012)
- Main Title:
- Reproducibility of rapid short echo time CSI at 3 tesla for clinical applications
- Authors:
- Van Cauter, Sofie
Sima, Diana M.
Luts, Jan
ter Beek, Leon
Ribbens, Annemie
Peeters, Ronald R.
Osorio Garcia, Maria I.
Li, Yuquan
Sunaert, Stefan
Van Gool, Stefaan W.
Van Huffel, Sabine
Himmelreich, Uwe - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To validate the reproducibility of a chemical shift imaging (CSI) acquisition protocol with parallel imaging, using automated repositioning software.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>Ten volunteers were imaged three times on two different 3 Tesla (T) MRI scanners, receiving anatomical imaging and two identical CSI measurements, using automated repositioning software for consistent repositioning of the CSI grid. Offcenter parameters of the CSI plane were analyzed. Coefficients of variation (CoV), Cramér‐Rao lower bounds (CRLB), intraclass correlation coefficients (ICC), and coefficients of repeatability (CoR) for immediate repetition and between scanners were calculated for N‐acetylaspartate, total choline, creatine, myo‐inositol (Myo) and glutamine+glutamate (Glx). Proportions of variance reflecting the effect of voxel location, volunteer, repetition, time instance and scanner were calculated from an analysis of variance analysis.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>The offcenter vector and angulations of the CSI grid differed less than 1 mm and 2° between all measurements. The mean CoV and CRLB were less than 30% for all metabolites, except for Myo. The variance due to voxel location in the volume of interest and the error represent the largest<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To validate the reproducibility of a chemical shift imaging (CSI) acquisition protocol with parallel imaging, using automated repositioning software.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>Ten volunteers were imaged three times on two different 3 Tesla (T) MRI scanners, receiving anatomical imaging and two identical CSI measurements, using automated repositioning software for consistent repositioning of the CSI grid. Offcenter parameters of the CSI plane were analyzed. Coefficients of variation (CoV), Cramér‐Rao lower bounds (CRLB), intraclass correlation coefficients (ICC), and coefficients of repeatability (CoR) for immediate repetition and between scanners were calculated for N‐acetylaspartate, total choline, creatine, myo‐inositol (Myo) and glutamine+glutamate (Glx). Proportions of variance reflecting the effect of voxel location, volunteer, repetition, time instance and scanner were calculated from an analysis of variance analysis.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>The offcenter vector and angulations of the CSI grid differed less than 1 mm and 2° between all measurements. The mean CoV and CRLB were less than 30% for all metabolites, except for Myo. The variance due to voxel location in the volume of interest and the error represent the largest contributions in variability. The ICC is the lowest for Myo and Glx. CoR for immediate repetition and between scanners display values between 22 and 83%.</p> </sec> <sec id="abs1-4" sec-type="section"> <title>Conclusion:</title> <p>We propose a CSI protocol with acceptable reproducibility, applicable in clinical routine. J. Magn. Reson. Imaging 2013;37:445–456. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 37:Issue 2(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 37:Issue 2(2013)
- Issue Display:
- Volume 37, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 37
- Issue:
- 2
- Issue Sort Value:
- 2013-0037-0002-0000
- Page Start:
- 445
- Page End:
- 456
- Publication Date:
- 2012-09-25
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23820 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3818.xml