DC‐gated high resolution three‐dimensional lung imaging during free‐breathing. Issue 3 (17th September 2012)
- Record Type:
- Journal Article
- Title:
- DC‐gated high resolution three‐dimensional lung imaging during free‐breathing. Issue 3 (17th September 2012)
- Main Title:
- DC‐gated high resolution three‐dimensional lung imaging during free‐breathing
- Authors:
- Weick, Stefan
Breuer, Felix A.
Ehses, Philipp
Völker, Michael
Hintze, Christian
Biederer, Jürgen
Jakob, Peter M. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To use the acquisition of the <italic>k</italic>‐space center signal (DC signal) implemented into a Cartesian three‐dimensional (3D) FLASH sequence for retrospective respiratory self‐gating and, thus, for the examination of the whole human lung in high spatial resolution during free breathing.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>Volunteer as well as patient measurements were performed under free breathing conditions. The DC signal is acquired after the actual image data acquisition within each excitation of a 3D FLASH sequence. The DC signal is then used to track respiratory motion for retrospective respiratory gating.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>It is shown that the acquisition of the DC signal after the imaging module can be used in a 3D FLASH sequence to extract respiratory motion information for retrospective respiratory self‐gating and allows for shorter echo times (TE) and therefore increased lung parenchyma SNR.</p> </sec> <sec id="abs1-4" sec-type="section"> <title>Conclusion:</title> <p>The acquisition of the DC signal after image signal acquisition allows successful retrospective gating, enabling the reconstruction of high resolution images of the whole human lung under free breathing conditions. J. Magn. Reson. Imaging<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To use the acquisition of the <italic>k</italic>‐space center signal (DC signal) implemented into a Cartesian three‐dimensional (3D) FLASH sequence for retrospective respiratory self‐gating and, thus, for the examination of the whole human lung in high spatial resolution during free breathing.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>Volunteer as well as patient measurements were performed under free breathing conditions. The DC signal is acquired after the actual image data acquisition within each excitation of a 3D FLASH sequence. The DC signal is then used to track respiratory motion for retrospective respiratory gating.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>It is shown that the acquisition of the DC signal after the imaging module can be used in a 3D FLASH sequence to extract respiratory motion information for retrospective respiratory self‐gating and allows for shorter echo times (TE) and therefore increased lung parenchyma SNR.</p> </sec> <sec id="abs1-4" sec-type="section"> <title>Conclusion:</title> <p>The acquisition of the DC signal after image signal acquisition allows successful retrospective gating, enabling the reconstruction of high resolution images of the whole human lung under free breathing conditions. J. Magn. Reson. Imaging 2013;37:727–732. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 37:Issue 3(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 37:Issue 3(2013)
- Issue Display:
- Volume 37, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 37
- Issue:
- 3
- Issue Sort Value:
- 2013-0037-0003-0000
- Page Start:
- 727
- Page End:
- 732
- Publication Date:
- 2012-09-17
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23798 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3240.xml