Automatic segmentation of white matter hyperintensities by an extended FitzHugh & nagumo reaction diffusion model. Issue 2 (28th September 2012)
- Record Type:
- Journal Article
- Title:
- Automatic segmentation of white matter hyperintensities by an extended FitzHugh & nagumo reaction diffusion model. Issue 2 (28th September 2012)
- Main Title:
- Automatic segmentation of white matter hyperintensities by an extended FitzHugh & nagumo reaction diffusion model
- Authors:
- Ji, Shuangxi
Ye, Changqing
Li, Fan
Sun, Wei
Zhang, Jue
Huang, Yining
Fang, Jing - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To evaluate the efficiency and reproducibility of the extended FitzHugh &amp; Nagumo (FHN) reaction‐diffusion model proposed in this study for white matter hyperintensities (WMH) segmentation.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>Five types of magnetic resonance T2‐weighted fluid‐attenuated inversion‐recovery (T2FLAIR) images of 127 patients with different scanning parameters from five clinical scanner systems were selected for this study. After skull and scalp removal and denoise, the T2FLAIR images were processed by the proposed extended FHN model to obtain WMH. This new technique replaced the global threshold constant with a local threshold matrix.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>There was no significant difference between the segmentation results of the training set and the manual contouring against those between the test set and the manual contouring based on similarity index (SI) values (<italic>P</italic> = 0.5217). The SI values of the five types of T2FLAIR images were 86.0% ± 15.4%, 85.8% ± 10.5%, 84.1% ± 14.8%, 87.2% ± 14.6%, 86.3% ± 12.7%, respectively, comparing the segmentation results using the proposed method to the manual delineations. The overall SI value of the images was 86.5% ± 14.5%. This approach also demonstrated a better WMH<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To evaluate the efficiency and reproducibility of the extended FitzHugh &amp; Nagumo (FHN) reaction‐diffusion model proposed in this study for white matter hyperintensities (WMH) segmentation.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>Five types of magnetic resonance T2‐weighted fluid‐attenuated inversion‐recovery (T2FLAIR) images of 127 patients with different scanning parameters from five clinical scanner systems were selected for this study. After skull and scalp removal and denoise, the T2FLAIR images were processed by the proposed extended FHN model to obtain WMH. This new technique replaced the global threshold constant with a local threshold matrix.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>There was no significant difference between the segmentation results of the training set and the manual contouring against those between the test set and the manual contouring based on similarity index (SI) values (<italic>P</italic> = 0.5217). The SI values of the five types of T2FLAIR images were 86.0% ± 15.4%, 85.8% ± 10.5%, 84.1% ± 14.8%, 87.2% ± 14.6%, 86.3% ± 12.7%, respectively, comparing the segmentation results using the proposed method to the manual delineations. The overall SI value of the images was 86.5% ± 14.5%. This approach also demonstrated a better WMH segmentation performance over its classic form (<italic>P</italic> &lt; 0.001).</p> </sec> <sec id="abs1-4" sec-type="section"> <title>Conclusion:</title> <p>The proposed approach is efficient and could provide a more effective and convenient tool for clinical quantitative WMH analysis. J. Magn. Reson. Imaging 2013;37:343–350. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 37:Issue 2(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 37:Issue 2(2013)
- Issue Display:
- Volume 37, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 37
- Issue:
- 2
- Issue Sort Value:
- 2013-0037-0002-0000
- Page Start:
- 343
- Page End:
- 350
- Publication Date:
- 2012-09-28
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23836 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3818.xml