Rapid freehand MR‐guided percutaneous needle interventions: An image‐based approach to improve workflow and feasibility. Issue 5 (18th January 2013)
- Record Type:
- Journal Article
- Title:
- Rapid freehand MR‐guided percutaneous needle interventions: An image‐based approach to improve workflow and feasibility. Issue 5 (18th January 2013)
- Main Title:
- Rapid freehand MR‐guided percutaneous needle interventions: An image‐based approach to improve workflow and feasibility
- Authors:
- Rothgang, Eva
Gilson, Wesley D.
Wacker, Frank
Hornegger, Joachim
Lorenz, Christine H.
Weiss, Clifford R. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To develop and evaluate software‐based methods for improving the workflow of magnetic resonance (MR)‐guided percutaneous interventions.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>A set of methods was developed that allows the user to: 1) plan an entire procedure, 2) directly apply this plan to skin entry site localization without further imaging, and 3) place a needle under real‐time MR guidance with automatic alignment of three orthogonal slices along a planned trajectory with preference to the principal patient axes. To validate targeting accuracy and time, phantom experiments (96 targets) and in vivo paraspinal and kidney needle punctures in two pigs (55 targets) were performed. The influence of trajectory obliquity, level of experience, and organ motion on targeting accuracy and time was analyzed.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>Mean targeting error was 1.8 ± 0.9 mm (in vitro) and 2.9 ± 1.0 mm (in vivo) in all directions. No statistically significant differences in targeting accuracy between single‐ and double‐oblique trajectories, novice and expert users, or paraspinal and kidney punctures were observed. The average time (in vivo) from trajectory planning to verification of accurate needle placement was 6 minutes.</p> </sec> <sec id="abs1-4"<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To develop and evaluate software‐based methods for improving the workflow of magnetic resonance (MR)‐guided percutaneous interventions.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>A set of methods was developed that allows the user to: 1) plan an entire procedure, 2) directly apply this plan to skin entry site localization without further imaging, and 3) place a needle under real‐time MR guidance with automatic alignment of three orthogonal slices along a planned trajectory with preference to the principal patient axes. To validate targeting accuracy and time, phantom experiments (96 targets) and in vivo paraspinal and kidney needle punctures in two pigs (55 targets) were performed. The influence of trajectory obliquity, level of experience, and organ motion on targeting accuracy and time was analyzed.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>Mean targeting error was 1.8 ± 0.9 mm (in vitro) and 2.9 ± 1.0 mm (in vivo) in all directions. No statistically significant differences in targeting accuracy between single‐ and double‐oblique trajectories, novice and expert users, or paraspinal and kidney punctures were observed. The average time (in vivo) from trajectory planning to verification of accurate needle placement was 6 minutes.</p> </sec> <sec id="abs1-4" sec-type="section"> <title>Conclusion:</title> <p>The developed methods allow for accurate needle placement along complex trajectories and are anticipated to reduce table time for MR‐guided percutaneous needle interventions. J. Magn. Reson. Imaging 2013;37:1202–1212. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 37:Issue 5(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 37:Issue 5(2013)
- Issue Display:
- Volume 37, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 37
- Issue:
- 5
- Issue Sort Value:
- 2013-0037-0005-0000
- Page Start:
- 1202
- Page End:
- 1212
- Publication Date:
- 2013-01-18
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23894 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4397.xml