Subject‐specific models of susceptibility‐induced B0 field variations in breast MRI. Issue 1 (3rd August 2012)
- Record Type:
- Journal Article
- Title:
- Subject‐specific models of susceptibility‐induced B0 field variations in breast MRI. Issue 1 (3rd August 2012)
- Main Title:
- Subject‐specific models of susceptibility‐induced B0 field variations in breast MRI
- Authors:
- Jordan, Caroline D.
Daniel, Bruce L.
Koch, Kevin M.
Yu, Huanzhou
Conolly, Steve
Hargreaves, Brian A. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To rapidly calculate and validate subject‐specific field maps based on the three‐dimensional shape of the bilateral breast volume.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>Ten healthy female volunteers were scanned at 3 Tesla using a multi‐echo sequence that provides water, fat, in‐phase, out‐of‐phase, and field map images. A shape‐specific binary mask was automatically generated to calculate a computed field map using a dipole field model. The measured and computed field maps were compared by visualizing the spatial distribution of the difference field map, the mean absolute error, and the 80% distribution widths of frequency histograms.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>The 10 computed field maps had a mean absolute error of 38 Hz (0.29 ppm) compared with the measured field maps. The average 80% distribution widths for the histograms of all of the computed, measured, and difference field maps are 205 Hz, 233 Hz, and 120 Hz, respectively.</p> </sec> <sec id="abs1-4" sec-type="section"> <title>Conclusion:</title> <p>The computed field maps had substantial overall agreement with the measured field maps, indicating that breast MRI field maps can be computed based on the air–tissue interfaces. These estimates may provide a predictive model for field<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <sec id="abs1-1" sec-type="section"> <title>Purpose:</title> <p>To rapidly calculate and validate subject‐specific field maps based on the three‐dimensional shape of the bilateral breast volume.</p> </sec> <sec id="abs1-2" sec-type="section"> <title>Materials and Methods:</title> <p>Ten healthy female volunteers were scanned at 3 Tesla using a multi‐echo sequence that provides water, fat, in‐phase, out‐of‐phase, and field map images. A shape‐specific binary mask was automatically generated to calculate a computed field map using a dipole field model. The measured and computed field maps were compared by visualizing the spatial distribution of the difference field map, the mean absolute error, and the 80% distribution widths of frequency histograms.</p> </sec> <sec id="abs1-3" sec-type="section"> <title>Results:</title> <p>The 10 computed field maps had a mean absolute error of 38 Hz (0.29 ppm) compared with the measured field maps. The average 80% distribution widths for the histograms of all of the computed, measured, and difference field maps are 205 Hz, 233 Hz, and 120 Hz, respectively.</p> </sec> <sec id="abs1-4" sec-type="section"> <title>Conclusion:</title> <p>The computed field maps had substantial overall agreement with the measured field maps, indicating that breast MRI field maps can be computed based on the air–tissue interfaces. These estimates may provide a predictive model for field variations and thus have the potential to improve applications in breast MRI. J. Magn. Reson. Imaging 2013;37:227–232. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 37:Issue 1(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 37:Issue 1(2013)
- Issue Display:
- Volume 37, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2013-0037-0001-0000
- Page Start:
- 227
- Page End:
- 232
- Publication Date:
- 2012-08-03
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23762 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3396.xml