Variations in BOLD response latency estimated from event‐related fMRI at 3T: Comparisons between gradient‐echo and Spin‐echo. Issue 3 (16th August 2013)
- Record Type:
- Journal Article
- Title:
- Variations in BOLD response latency estimated from event‐related fMRI at 3T: Comparisons between gradient‐echo and Spin‐echo. Issue 3 (16th August 2013)
- Main Title:
- Variations in BOLD response latency estimated from event‐related fMRI at 3T: Comparisons between gradient‐echo and Spin‐echo
- Authors:
- Yeh, Mei‐Yu
Wu, Changwei W.
Kuan, Wan‐Chun
Wei, Pei‐Shan
Wan, Yung‐Liang
Wai, Yau‐Yau
Weng, Hsu‐Huei
Liu, Ho‐Ling - Abstract:
- <abstract abstract-type="main"> <title>ABSTRACT</title> <p>Functional magnetic resonance imaging (fMRI) commonly uses gradient‐recalled echo (GRE) signals to detect regional hemodynamic variations originating from neural activities. While the spatial localization of activation shows promising applications, indexing temporal response remains a poor mechanism for detecting the timing of neural activity. Particularly, the hemodynamic response may fail to resolve sub‐second temporal differences between brain regions because of its signal origin or noise in data, or both. This study aimed at evaluating the performance of latency estimation using different fMRI techniques, with two event‐related experiments at 3T. Experiment I evaluated latency variations within the visual cortex and their relationship with contrast‐to‐noise ratios (CNRs) for GRE, spin echo (SE), and diffusion‐weighted SE (DWSE). Experiment II used delayed visual stimuli between two hemifields (delay time = 0, 250, and 500 ms, respectively) to assess the temporal resolving power of three protocols: GRE<sub>TR1000</sub>, GRE<sub>TR500</sub>, and SE<sub>TR1000</sub>. The results of experiment I showed the earliest latency with DWSE, followed by SE, and then GRE. Latency variations decreased as CNR increased. However, similar variations were found between GRE and SE, when the latter had lower CNR. In experiment II, measured stimulus delays from all conditions were significantly correlated with preset stimulus delays.<abstract abstract-type="main"> <title>ABSTRACT</title> <p>Functional magnetic resonance imaging (fMRI) commonly uses gradient‐recalled echo (GRE) signals to detect regional hemodynamic variations originating from neural activities. While the spatial localization of activation shows promising applications, indexing temporal response remains a poor mechanism for detecting the timing of neural activity. Particularly, the hemodynamic response may fail to resolve sub‐second temporal differences between brain regions because of its signal origin or noise in data, or both. This study aimed at evaluating the performance of latency estimation using different fMRI techniques, with two event‐related experiments at 3T. Experiment I evaluated latency variations within the visual cortex and their relationship with contrast‐to‐noise ratios (CNRs) for GRE, spin echo (SE), and diffusion‐weighted SE (DWSE). Experiment II used delayed visual stimuli between two hemifields (delay time = 0, 250, and 500 ms, respectively) to assess the temporal resolving power of three protocols: GRE<sub>TR1000</sub>, GRE<sub>TR500</sub>, and SE<sub>TR1000</sub>. The results of experiment I showed the earliest latency with DWSE, followed by SE, and then GRE. Latency variations decreased as CNR increased. However, similar variations were found between GRE and SE, when the latter had lower CNR. In experiment II, measured stimulus delays from all conditions were significantly correlated with preset stimulus delays. Inter‐subject variation in the measured delay was found to be greatest with GRE<sub>TR1000</sub>, followed by GRE<sub>TR500</sub>, and the least with SE<sub>TR1000</sub>. Conclusively, blood oxygenation level‐dependent responses obtained from GRE exhibit greater CNR but no compromised latency variations in the visual cortex. SE is potentially capable of improving the performance of latency estimation, especially for group analysis. © 2013 Wiley Periodicals, Inc. Int J Imaging Syst Technol, 23, 215–221, 2013</p> </abstract> … (more)
- Is Part Of:
- International journal of imaging systems and technology. Volume 23:Issue 3(2013:Sep.)
- Journal:
- International journal of imaging systems and technology
- Issue:
- Volume 23:Issue 3(2013:Sep.)
- Issue Display:
- Volume 23, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2013-0023-0003-0000
- Page Start:
- 215
- Page End:
- 221
- Publication Date:
- 2013-08-16
- Subjects:
- Imaging systems -- Periodicals
Image processing -- Periodicals
621.367 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-1098 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ima.22054 ↗
- Languages:
- English
- ISSNs:
- 0899-9457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.299000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3013.xml