GlyXalign: High‐throughput migration time alignment preprocessing of electrophoretic data retrieved via multiplexed capillary gel electrophoresis with laser‐induced fluorescence detection‐based glycoprofiling. Issue 16 (8th July 2013)
- Record Type:
- Journal Article
- Title:
- GlyXalign: High‐throughput migration time alignment preprocessing of electrophoretic data retrieved via multiplexed capillary gel electrophoresis with laser‐induced fluorescence detection‐based glycoprofiling. Issue 16 (8th July 2013)
- Main Title:
- GlyXalign: High‐throughput migration time alignment preprocessing of electrophoretic data retrieved via multiplexed capillary gel electrophoresis with laser‐induced fluorescence detection‐based glycoprofiling
- Authors:
- Behne, Alexander
Muth, Thilo
Borowiak, Matthias
Reichl, Udo
Rapp, Erdmann
Guttman, Andras - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Glycomics has become a rapidly emerging field and monitoring of protein glycosylation is needed to ensure quality and consistency during production processes of biologicals such as therapeutic antibodies or vaccines. Glycoanalysis via multiplexed CGE with LIF detection (xCGE‐LIF) represents a powerful technique featuring high resolution, high sensitivity as well as high‐throughput performance. However, sample data retrieved from this method exhibit challenges for downstream computational analysis due to intersample migration time shifts as well as stretching and compression of electropherograms. Here, we present glyXalign, a freely available and easy‐to‐use software package to automatically correct for distortions in xCGE‐LIF based glycan data. We demonstrate its ability to outperform conventional algorithms such as dynamic time warping and correlation optimized warping in terms of processing time and alignment accuracy for high‐resolution datasets. Built upon a set of rapid algorithms, the tool includes an intuitive graphical user interface and allows full control over all parameters. Additionally, it visualizes the alignment process and enables the user to readjust misaligned results. Software and documentation are available at http://www.glyxera.com.</p> </abstract>
- Is Part Of:
- Electrophoresis. Volume 34:Issue 16(2013:Aug.)
- Journal:
- Electrophoresis
- Issue:
- Volume 34:Issue 16(2013:Aug.)
- Issue Display:
- Volume 34, Issue 16 (2013)
- Year:
- 2013
- Volume:
- 34
- Issue:
- 16
- Issue Sort Value:
- 2013-0034-0016-0000
- Page Start:
- 2311
- Page End:
- 2315
- Publication Date:
- 2013-07-08
- Subjects:
- Electrophoresis -- Periodicals
Electrophoresis -- Periodicals
541.372 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2683 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elps.201200696 ↗
- Languages:
- English
- ISSNs:
- 0173-0835
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3706.378000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3271.xml