CA 125 Immunosensor Based on Poly‐Anthranilic Acid Modified Screen‐Printed Electrodes. Issue 1 (13th November 2012)
- Record Type:
- Journal Article
- Title:
- CA 125 Immunosensor Based on Poly‐Anthranilic Acid Modified Screen‐Printed Electrodes. Issue 1 (13th November 2012)
- Main Title:
- CA 125 Immunosensor Based on Poly‐Anthranilic Acid Modified Screen‐Printed Electrodes
- Authors:
- Taleat, Zahra
Ravalli, Andrea
Mazloum‐Ardakani, Mohammad
Marrazza, Giovanna - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>In this paper, two simple and sensitive approaches for CA 125 detection are presented by using antibody immobilized on poly‐anthranilic acid modified graphite screen‐printed electrodes. The first proposed approach is a label‐free impedimetric immunosensor. The immunoassay is based on poly‐anthranilic acid (PAA) modified graphite screen‐printed electrodes with subsequent covalently monoclonal antibody anti‐CA 125 immobilization. The modified screen‐printed electrodes are used to capture the protein from the sample solutions. A curve calibration by electrochemical impedance spectroscopy (EIS) was obtained. The second approach is based on a sandwich format. The monoclonal anti‐CA 125 antibodies immobilized on poly‐anthranilic acid modified graphite screen‐printed electrodes is used to capture the protein from the sample solution. The sandwich assay is then performed by adding secondary anti‐CA 125 antibodies labeled with gold nanoparticles (AuNPs). The antibody‐AuNPs captured onto immunosensor surface induced the silver deposition from a silver enhancer solution. The deposited AgNPs could be measured by anodic stripping analysis (ASV) in acid solution. A curve calibration by ASV was obtained. The experimental conditions were examined and were optimized using electrochemical impedance spectroscopy. The performance of both immunosensors in terms of sensitivity, reproducibility and selectivity were<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>In this paper, two simple and sensitive approaches for CA 125 detection are presented by using antibody immobilized on poly‐anthranilic acid modified graphite screen‐printed electrodes. The first proposed approach is a label‐free impedimetric immunosensor. The immunoassay is based on poly‐anthranilic acid (PAA) modified graphite screen‐printed electrodes with subsequent covalently monoclonal antibody anti‐CA 125 immobilization. The modified screen‐printed electrodes are used to capture the protein from the sample solutions. A curve calibration by electrochemical impedance spectroscopy (EIS) was obtained. The second approach is based on a sandwich format. The monoclonal anti‐CA 125 antibodies immobilized on poly‐anthranilic acid modified graphite screen‐printed electrodes is used to capture the protein from the sample solution. The sandwich assay is then performed by adding secondary anti‐CA 125 antibodies labeled with gold nanoparticles (AuNPs). The antibody‐AuNPs captured onto immunosensor surface induced the silver deposition from a silver enhancer solution. The deposited AgNPs could be measured by anodic stripping analysis (ASV) in acid solution. A curve calibration by ASV was obtained. The experimental conditions were examined and were optimized using electrochemical impedance spectroscopy. The performance of both immunosensors in terms of sensitivity, reproducibility and selectivity were studied.</p> </abstract> … (more)
- Is Part Of:
- Electroanalysis. Volume 25:Issue 1(2013:Jan.)
- Journal:
- Electroanalysis
- Issue:
- Volume 25:Issue 1(2013:Jan.)
- Issue Display:
- Volume 25, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2013-0025-0001-0000
- Page Start:
- 269
- Page End:
- 277
- Publication Date:
- 2012-11-13
- Subjects:
- Electrochemical analysis -- Periodicals
Chemistry, Analytical -- Periodicals
Electrochemistry -- Periodicals
543.4 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4109 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elan.201200425 ↗
- Languages:
- English
- ISSNs:
- 1040-0397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.789000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3117.xml