A New Validated Potentiometric Method for Batch and Continuous Quality Control Monitoring of Oseltamivir Phosphate (Taminil) in Drug Formulations and Biological Fluids. Issue 2 (28th November 2012)
- Record Type:
- Journal Article
- Title:
- A New Validated Potentiometric Method for Batch and Continuous Quality Control Monitoring of Oseltamivir Phosphate (Taminil) in Drug Formulations and Biological Fluids. Issue 2 (28th November 2012)
- Main Title:
- A New Validated Potentiometric Method for Batch and Continuous Quality Control Monitoring of Oseltamivir Phosphate (Taminil) in Drug Formulations and Biological Fluids
- Authors:
- Hassan, Saad S. M.
EL‐Nashar, Rasha M.
El‐Tantawy, Aliaa S. M. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>A new validated potentiometric method is described for batch and continuous quality control monitoring of the drug oseltamivir phosphate (Taminil) (OST). The method involves the development of a potentiometric sensor responsive to the drug based on the use of the ion‐association complex of (OST<sup>+</sup>) cation with phosphomolybdate anion (PMA<sup>−</sup>) as an electroactive material in a poly(vinyl chloride) matrix membrane plasticized with <italic>o</italic>‐nitrophenyloctyl ether (<italic>o</italic>‐NPOE). Optimization of the performance characteristics of the sensor is described. A membrane incorporating the OST‐PMA‐NPOE complex in a tubular flow through detector is used in a two channel flow injection set up for continuous monitoring of the drug at a frequency of ∼30 samples h<sup>−1</sup>. The sensor shows fast near‐Nernstian response for OST over the concentration range 5.2×10<sup>−5</sup>–0.8×10<sup>−2</sup> M (21.34 µg mL<sup>−1</sup>–3.23 mg mL<sup>−1</sup>) with a detection limit of 9.1×10<sup>−6</sup> M (3.73 µg mL<sup>−1</sup>) over the pH range 4.6–6.1. The sensor displays good selectivity for OST drug over some basic drugs, inorganic cations, excipients and diluents commonly used in the drug formulations. Validation of the assay method is tested by measuring the lower detection limit, range, linearity, bias, trueness, accuracy, precision, and between‐day‐variability, within day<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>A new validated potentiometric method is described for batch and continuous quality control monitoring of the drug oseltamivir phosphate (Taminil) (OST). The method involves the development of a potentiometric sensor responsive to the drug based on the use of the ion‐association complex of (OST<sup>+</sup>) cation with phosphomolybdate anion (PMA<sup>−</sup>) as an electroactive material in a poly(vinyl chloride) matrix membrane plasticized with <italic>o</italic>‐nitrophenyloctyl ether (<italic>o</italic>‐NPOE). Optimization of the performance characteristics of the sensor is described. A membrane incorporating the OST‐PMA‐NPOE complex in a tubular flow through detector is used in a two channel flow injection set up for continuous monitoring of the drug at a frequency of ∼30 samples h<sup>−1</sup>. The sensor shows fast near‐Nernstian response for OST over the concentration range 5.2×10<sup>−5</sup>–0.8×10<sup>−2</sup> M (21.34 µg mL<sup>−1</sup>–3.23 mg mL<sup>−1</sup>) with a detection limit of 9.1×10<sup>−6</sup> M (3.73 µg mL<sup>−1</sup>) over the pH range 4.6–6.1. The sensor displays good selectivity for OST drug over some basic drugs, inorganic cations, excipients and diluents commonly used in the drug formulations. Validation of the assay method is tested by measuring the lower detection limit, range, linearity, bias, trueness, accuracy, precision, and between‐day‐variability, within day reproducibility, selectivity and ruggedness (robustness). The results reveal good potentiometric performance of the proposed sensor for determination of OST in pharmaceutical capsules and in biological fluid matrices as well as for testing the dissolution profile of the drug and drug homogeneity.</p> </abstract> … (more)
- Is Part Of:
- Electroanalysis. Volume 25:Issue 2(2013:Feb.)
- Journal:
- Electroanalysis
- Issue:
- Volume 25:Issue 2(2013:Feb.)
- Issue Display:
- Volume 25, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 25
- Issue:
- 2
- Issue Sort Value:
- 2013-0025-0002-0000
- Page Start:
- 408
- Page End:
- 416
- Publication Date:
- 2012-11-28
- Subjects:
- Electrochemical analysis -- Periodicals
Chemistry, Analytical -- Periodicals
Electrochemistry -- Periodicals
543.4 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4109 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elan.201200437 ↗
- Languages:
- English
- ISSNs:
- 1040-0397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.789000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3042.xml