Reproducibility comparison among multiangle spectrophotometers. Issue 3 (13th February 2012)
- Record Type:
- Journal Article
- Title:
- Reproducibility comparison among multiangle spectrophotometers. Issue 3 (13th February 2012)
- Main Title:
- Reproducibility comparison among multiangle spectrophotometers
- Authors:
- Perales, Esther
Chorro, Elísabet
Viqueira, Valentín
Martínez‐Verdú, Francisco M. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>New color‐measuring instruments known as multiangle spectrophotometers have been recently created to measure and characterize the goniochromism of special‐effect pigments in many materials with a particular visual appearance (metallic, interference, pearlescent, sparkle, or glitter). These devices measure the gonioapparent color from the spectral relative reflectance factor and the L*a*b* values of the sample with different illumination and observation angles. These angles usually coincide with requirements marked in American Society for Testing and Materials (ASTM) and Deutsches Institut Für Normung standards relating to the gonioapparent color, but the results of comparisons between these instruments are still inconclusive. Therefore, the main purpose of this study is to compare several multiangle spectrophotometers at a reproducibility level according to ASTM E2214‐08 guidelines. In particular, we compared two X‐Rite multi‐gonio spectrophotometers (MA98 and MA68II), a Datacolor multi‐gonio spectrophotometer (FX10), and a BYK multi‐gonio spectrophotometer (BYK‐mac). These instruments share only five common measurement geometries: 45° × −30° (as 15°), 45° × −20° (as 25°), 45° × 0° (as 45°), 45° × 30° (as 75°), 45° × 65° (as 110°). Specific statistical studies were used for the reproducibility comparison, including a Hotelling test and a statistical intercomparison test to determine the<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>New color‐measuring instruments known as multiangle spectrophotometers have been recently created to measure and characterize the goniochromism of special‐effect pigments in many materials with a particular visual appearance (metallic, interference, pearlescent, sparkle, or glitter). These devices measure the gonioapparent color from the spectral relative reflectance factor and the L*a*b* values of the sample with different illumination and observation angles. These angles usually coincide with requirements marked in American Society for Testing and Materials (ASTM) and Deutsches Institut Für Normung standards relating to the gonioapparent color, but the results of comparisons between these instruments are still inconclusive. Therefore, the main purpose of this study is to compare several multiangle spectrophotometers at a reproducibility level according to ASTM E2214‐08 guidelines. In particular, we compared two X‐Rite multi‐gonio spectrophotometers (MA98 and MA68II), a Datacolor multi‐gonio spectrophotometer (FX10), and a BYK multi‐gonio spectrophotometer (BYK‐mac). These instruments share only five common measurement geometries: 45° × −30° (as 15°), 45° × −20° (as 25°), 45° × 0° (as 45°), 45° × 30° (as 75°), 45° × 65° (as 110°). Specific statistical studies were used for the reproducibility comparison, including a Hotelling test and a statistical intercomparison test to determine the confidence interval of the partial color differences ΔL*, Δa*, Δb*, and the total color difference ΔE*<sub>ab</sub>. This was conducted using a database collection of 88 metallic and pearlescent samples that were measured 20 times without the replacement of all the instruments. The final findings show that in most measurement geometries, the reproducibility differences between pairs of instruments are statistically significant, although in general, there is a better reproducibility level at certain common geometries for newer instruments (MA98 and BYK‐mac). This means that these differences are due to systematic or bias errors (angle tolerances for each geometry, photometric scales, white standards, etc.), but not exclusively to random errors. However, neither of the statistical tests used is valid to discriminate and quantify the detected bias errors in this comparison between instruments. © 2012 Wiley Periodicals, Inc. Col Res Appl, 38, 160–167, 2013.</p> </abstract> … (more)
- Is Part Of:
- Color research & application. Volume 38:Issue 3(2013:Jun.)
- Journal:
- Color research & application
- Issue:
- Volume 38:Issue 3(2013:Jun.)
- Issue Display:
- Volume 38, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 3
- Issue Sort Value:
- 2013-0038-0003-0000
- Page Start:
- 160
- Page End:
- 167
- Publication Date:
- 2012-02-13
- Subjects:
- Color -- Periodicals
535 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1520-6378 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/col.21719 ↗
- Languages:
- English
- ISSNs:
- 0361-2317
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3320.677000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4212.xml