Polyaniline/Prussian‐Blue‐Based Amperometric Biosensor for Detection of Uric Acid. Issue 2 (22nd November 2012)
- Record Type:
- Journal Article
- Title:
- Polyaniline/Prussian‐Blue‐Based Amperometric Biosensor for Detection of Uric Acid. Issue 2 (22nd November 2012)
- Main Title:
- Polyaniline/Prussian‐Blue‐Based Amperometric Biosensor for Detection of Uric Acid
- Authors:
- Thakur, Bhawana
Sawant, Shilpa N. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>Polyaniline/Prussian blue (PANI‐PB) composite was electrochemically deposited on a platinum electrode. The properties of the PANI‐PB‐modified electrode were exploited in terms of its response toward H<sub>2</sub>O<sub>2</sub> sensing by using cyclic voltammetry, and were found to be more effectual than the PANI‐modified electrode in the low‐potential range. The PANI‐PB‐modified electrode was further used for the bioanalysis of uric acid by immobilization of the enzyme uricase. The electrode was characterized at various stages of modification by scanning electron microscopy (SEM), IR spectroscopy, and cyclic voltammetry. The biosensor gave a linear response for uric acid in the concentration range 10–160 μ<sc>M</sc> with a sensitivity of 160 μA m<sc>M</sc><sup>−1</sup> cm<sup>−2</sup>. The main advantage of the PANI‐PB composite electrode is its low working potential (0 V vs. Ag/AgCl) for the estimation of uric acid, which enables the elimination of plausible interfering effects caused by analytes present in real samples. The biosensor was selective to uric acid and did not respond to analytes such as ascorbic acid, glucose, and urea. The sensor electrode retained its selectivity and sensitivity for seven days if stored at −18 °C. The biosensor also displayed a satisfactory performance for the detection of uric acid in human blood serum samples.</p> </abstract>
- Is Part Of:
- ChemPlusChem. Volume 78:Issue 2(2013:Feb.)
- Journal:
- ChemPlusChem
- Issue:
- Volume 78:Issue 2(2013:Feb.)
- Issue Display:
- Volume 78, Issue 2 (2013)
- Year:
- 2013
- Volume:
- 78
- Issue:
- 2
- Issue Sort Value:
- 2013-0078-0002-0000
- Page Start:
- 166
- Page End:
- 174
- Publication Date:
- 2012-11-22
- Subjects:
- Chemistry -- Periodicals
540.5 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2192-6506 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cplu.201200222 ↗
- Languages:
- English
- ISSNs:
- 2192-6506
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4144.xml