Transcatheter PFO closure with GORE® septal occluder: Early and mid‐term clinical results. Issue 6 (30th July 2013)
- Record Type:
- Journal Article
- Title:
- Transcatheter PFO closure with GORE® septal occluder: Early and mid‐term clinical results. Issue 6 (30th July 2013)
- Main Title:
- Transcatheter PFO closure with GORE® septal occluder: Early and mid‐term clinical results
- Authors:
- Butera, Gianfranco
Saracino, Antonio
Danna, Paolo
Sganzerla, Paolo
Chessa, Massimo
Carminati, Mario - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25106-sec-0001" sec-type="section"> <title>Background</title> <p>Transcatheter closure of patent foramen ovale (PFO) is a widespread procedure. However the "quest" for the ideal device is still ongoing. Here we present the procedural and early results of transcatheter closure of PFO with the GORE® Septal Occluder.</p> </sec> <sec id="ccd25106-sec-0002" sec-type="section"> <title>Methods</title> <p>Three Italian centers participated in a registry and collected data from 122 consecutive patients undergoing PFO closure by using GSO device. Indication for closure was previous stroke or transient cerebral ischemia in 110 and migraine in 12 subjects.</p> </sec> <sec id="ccd25106-sec-0003" sec-type="section"> <title>Results</title> <p>The procedure was successful in all patients. The procedure was performed under general anesthesia, fluoroscopic, and trans‐esophageal echocardiographic imaging in 80 subjects while it was performed with local anesthesia, fluoroscopic, and intracardiac echocardiographic monitoring in 42 subjects. Twenty patients received a 20 mm device, 70 patients received a 25 mm device, and 32 received a 30 mm device. Procedure and fluoroscopy times were 30 ± 20 and 5 ± 4 min, respectively. In three cases, the implanted device was retrieved because of unsatisfactory position. Four subjects (2.5%) experienced vascular complications. During a median follow‐up of 9 months<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25106-sec-0001" sec-type="section"> <title>Background</title> <p>Transcatheter closure of patent foramen ovale (PFO) is a widespread procedure. However the "quest" for the ideal device is still ongoing. Here we present the procedural and early results of transcatheter closure of PFO with the GORE® Septal Occluder.</p> </sec> <sec id="ccd25106-sec-0002" sec-type="section"> <title>Methods</title> <p>Three Italian centers participated in a registry and collected data from 122 consecutive patients undergoing PFO closure by using GSO device. Indication for closure was previous stroke or transient cerebral ischemia in 110 and migraine in 12 subjects.</p> </sec> <sec id="ccd25106-sec-0003" sec-type="section"> <title>Results</title> <p>The procedure was successful in all patients. The procedure was performed under general anesthesia, fluoroscopic, and trans‐esophageal echocardiographic imaging in 80 subjects while it was performed with local anesthesia, fluoroscopic, and intracardiac echocardiographic monitoring in 42 subjects. Twenty patients received a 20 mm device, 70 patients received a 25 mm device, and 32 received a 30 mm device. Procedure and fluoroscopy times were 30 ± 20 and 5 ± 4 min, respectively. In three cases, the implanted device was retrieved because of unsatisfactory position. Four subjects (2.5%) experienced vascular complications. During a median follow‐up of 9 months (range 1–18 months) seven patients experienced atrial arrhythmias and four of them required medical treatment. At six months follow‐up, at chest X‐ray in two cases there was evidence of fracture of two wires of the device. Devices were stable and no treatment was required. Moderate residual shunting was found in two patients at 6‐ and 12‐months follow‐up. No other complication occurred.</p> </sec> <sec id="ccd25106-sec-0004" sec-type="section"> <title>Conclusion</title> <p>GORE® Septal Occluder is an easy, safe, and effective device in closing PFO. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 82:Issue 6(2013:Nov. 15)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 82:Issue 6(2013:Nov. 15)
- Issue Display:
- Volume 82, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 82
- Issue:
- 6
- Issue Sort Value:
- 2013-0082-0006-0000
- Page Start:
- 944
- Page End:
- 949
- Publication Date:
- 2013-07-30
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.25106 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3546.xml