Delivering stents in congenital heart disease using the double‐wire technique: Technical considerations. Issue 7 (5th June 2013)
- Record Type:
- Journal Article
- Title:
- Delivering stents in congenital heart disease using the double‐wire technique: Technical considerations. Issue 7 (5th June 2013)
- Main Title:
- Delivering stents in congenital heart disease using the double‐wire technique: Technical considerations
- Authors:
- Brown, Stephen C.
Cools, Bjorn
Boshoff, Derize E.
Özbarlas, Nazan
Heying, Ruth
Budts, Werner
Buys, Daniël
Gewillig, Marc - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd24954-sec-0001" sec-type="section"> <title>Objectives</title> <p>To evaluate the use of a double‐wire technique to deliver stents.</p> </sec> <sec id="ccd24954-sec-0002" sec-type="section"> <title>Background</title> <p>Placement of a stent in lesions close to bifurcations or without an anatomic obstruction can be problematic.</p> </sec> <sec id="ccd24954-sec-0003" sec-type="section"> <title>Patients and Methods</title> <p>Stents were implanted in 12 patients between August 2010 and August 2012. Indications were complex anatomic obstruction in nine, external compression of pulmonary veins in two, and exclusion of an aortic aneurysm in one patient.</p> </sec> <sec id="ccd24954-sec-0004" sec-type="section"> <title>Results</title> <p>Median age and body weight of the group were 11.6 years (range: 1.6–34.8) and 36 kg (range: 10–78), respectively. All stents were delivered safely and the patency of all side vessels was maintained; the distal end of the stent was flared to a median ratio of 1.4 (range: 1.2–1.8). The clinical objective was met in all patients: in lesions with stenosis, diameter increased from 5.9 mm (range: 1–13) to 9.9 mm (range: 8–17) [<italic>P</italic> &lt; 0.01; 95% confidence interval (CI): 2.0–7.2]; oxygen saturations improved in the 2 patients after relief of the external pulmonary venous compression and in another an aortic aneurysm was excluded. One patient<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd24954-sec-0001" sec-type="section"> <title>Objectives</title> <p>To evaluate the use of a double‐wire technique to deliver stents.</p> </sec> <sec id="ccd24954-sec-0002" sec-type="section"> <title>Background</title> <p>Placement of a stent in lesions close to bifurcations or without an anatomic obstruction can be problematic.</p> </sec> <sec id="ccd24954-sec-0003" sec-type="section"> <title>Patients and Methods</title> <p>Stents were implanted in 12 patients between August 2010 and August 2012. Indications were complex anatomic obstruction in nine, external compression of pulmonary veins in two, and exclusion of an aortic aneurysm in one patient.</p> </sec> <sec id="ccd24954-sec-0004" sec-type="section"> <title>Results</title> <p>Median age and body weight of the group were 11.6 years (range: 1.6–34.8) and 36 kg (range: 10–78), respectively. All stents were delivered safely and the patency of all side vessels was maintained; the distal end of the stent was flared to a median ratio of 1.4 (range: 1.2–1.8). The clinical objective was met in all patients: in lesions with stenosis, diameter increased from 5.9 mm (range: 1–13) to 9.9 mm (range: 8–17) [<italic>P</italic> &lt; 0.01; 95% confidence interval (CI): 2.0–7.2]; oxygen saturations improved in the 2 patients after relief of the external pulmonary venous compression and in another an aortic aneurysm was excluded. One patient developed a hemothorax and one required blood transfusion for bleeding from the valve of the sheath.</p> </sec> <sec id="ccd24954-sec-0005" sec-type="section"> <title>Conclusions</title> <p>The double‐wire stenting technique is effective to accurately deliver and anchor stents into lesions close to side branches and bifurcations. Side branch patency is maintained; the clinical objective (gradient relief, aneurysm exclusion, relief of external compression) can safely be reached. Technique and balloon selection should be based on the underlying anatomical substrate. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 82:Issue 7(2013:Dec. 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 82:Issue 7(2013:Dec. 01)
- Issue Display:
- Volume 82, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 82
- Issue:
- 7
- Issue Sort Value:
- 2013-0082-0007-0000
- Page Start:
- 1156
- Page End:
- 1163
- Publication Date:
- 2013-06-05
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.24954 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4302.xml