Radiation dose of patients undergoing transcatheter aortic valve implantation: A comparison between edwards SAPIEN XT and medtronic corevalve aortic valve prostheses. Issue 4 (9th May 2013)
- Record Type:
- Journal Article
- Title:
- Radiation dose of patients undergoing transcatheter aortic valve implantation: A comparison between edwards SAPIEN XT and medtronic corevalve aortic valve prostheses. Issue 4 (9th May 2013)
- Main Title:
- Radiation dose of patients undergoing transcatheter aortic valve implantation: A comparison between edwards SAPIEN XT and medtronic corevalve aortic valve prostheses
- Authors:
- Steinvil, Arie
Aviram, Galit
Konigstein, Maayan
Abramowitz, Yigal
Halkin, Amir
Arbel, Yaron
Ben‐Gal, Yanai
Keren, Gad
Banai, Shmuel
Finkelstein, Ariel - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd24951-sec-0001" sec-type="section"> <title>Background</title> <p>The relative radiation dose (RD) of patients undergoing transcatheter aortic valve implantation (TAVI) with either the Edwards Sapien XT (ESX) or the Medtronic CoreValve (MCV) prostheses has not been studied in depth. Our aim was to quantify RD in uncomplicated transfemoral TAVI with either prosthesis.</p> </sec> <sec id="ccd24951-sec-0002" sec-type="section"> <title>Methods</title> <p>We analyzed 248 consecutive patients undergoing uncomplicated transfemoral TAVI between March 2009 and September 2012, at a single tertiary care facility. Total air Kerma, cumulated dose area product (DAP), and fluoroscopy time were determined in each case.</p> </sec> <sec id="ccd24951-sec-0003" sec-type="section"> <title>Results</title> <p>The ESX and MCV prostheses were implanted in 44 and 204 patients, respectively. Though mean fluoroscopy time was higher during ESX valve implantation, overall RD per total air Kerma and DAP was significantly higher during MCV implantation (<italic>P</italic> &lt; 0.05 for both comparisons). By multivariate regression analyses, prosthesis type was an independent predictor of RD according to both total air Kerma and DAP (<italic>r</italic><sup>2</sup> = 0. 498; <italic>P</italic> &lt; 0.01 and <italic>r</italic><sup>2</sup> = 0.363; <italic>P</italic> &lt; 0.01, respectively).</p> </sec> <sec<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd24951-sec-0001" sec-type="section"> <title>Background</title> <p>The relative radiation dose (RD) of patients undergoing transcatheter aortic valve implantation (TAVI) with either the Edwards Sapien XT (ESX) or the Medtronic CoreValve (MCV) prostheses has not been studied in depth. Our aim was to quantify RD in uncomplicated transfemoral TAVI with either prosthesis.</p> </sec> <sec id="ccd24951-sec-0002" sec-type="section"> <title>Methods</title> <p>We analyzed 248 consecutive patients undergoing uncomplicated transfemoral TAVI between March 2009 and September 2012, at a single tertiary care facility. Total air Kerma, cumulated dose area product (DAP), and fluoroscopy time were determined in each case.</p> </sec> <sec id="ccd24951-sec-0003" sec-type="section"> <title>Results</title> <p>The ESX and MCV prostheses were implanted in 44 and 204 patients, respectively. Though mean fluoroscopy time was higher during ESX valve implantation, overall RD per total air Kerma and DAP was significantly higher during MCV implantation (<italic>P</italic> &lt; 0.05 for both comparisons). By multivariate regression analyses, prosthesis type was an independent predictor of RD according to both total air Kerma and DAP (<italic>r</italic><sup>2</sup> = 0. 498; <italic>P</italic> &lt; 0.01 and <italic>r</italic><sup>2</sup> = 0.363; <italic>P</italic> &lt; 0.01, respectively).</p> </sec> <sec id="ccd24951-sec-0004" sec-type="section"> <title>Conclusion</title> <p>In uncomplicated transfemoral TAVI, RD is greater during MCV implantation than during ESX implantation. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 82:Issue 4(2013:Oct. 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 82:Issue 4(2013:Oct. 01)
- Issue Display:
- Volume 82, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 82
- Issue:
- 4
- Issue Sort Value:
- 2013-0082-0004-0000
- Page Start:
- E578
- Page End:
- E582
- Publication Date:
- 2013-05-09
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.24951 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4343.xml