Transhepatic approach to create stent fenestration in the extracardiac fontan conduit in a child with dextrocardia and interrupted inferior vena cava with azygos continuation. Issue 5 (7th August 2012)
- Record Type:
- Journal Article
- Title:
- Transhepatic approach to create stent fenestration in the extracardiac fontan conduit in a child with dextrocardia and interrupted inferior vena cava with azygos continuation. Issue 5 (7th August 2012)
- Main Title:
- Transhepatic approach to create stent fenestration in the extracardiac fontan conduit in a child with dextrocardia and interrupted inferior vena cava with azygos continuation
- Authors:
- Kobayashi, Daisuke
Turner, Daniel R.
Forbes, Thomas J. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Plastic bronchitis is a rare life‐threatening complication of Fontan operation. When medical treatment is ineffective in the setting of high systemic venous pressures, Fontan fenestration may be considered to decompress venous pressures and improve cardiac output by creation of the right‐to‐left shunting. However, transcatheter approach can be difficult in patients with complex venous anatomy. We report a 4‐year‐old girl born with hypoplastic left ventricle and heterotaxy syndrome, who developed plastic bronchitis following extracardiac Fontan procedure. Her venous anatomy was complex with dextrocardia and interrupted inferior vena cava with azygos continuation. Stent fenestration was successfully performed via transhepatic approach, which was selected based on the anatomical relationship (between extracardiac conduit, left atrium, and hepatic veins) delineated by pre‐catheterization cardiac MRI. Simultaneous transesophageal echocardiography guided the intervention. Her plastic bronchitis improved significantly in 3 months but slowly progressed after the stent fenestration. At her 8‐month follow‐up, stent fenestration remains open and she is currently under heart transplantation evaluation due to persistent plastic bronchitis. Treatment of plastic bronchitis can be undertaken with Fontan fenestration, with pre‐procedural MRI playing an essential role in patients with complex venous<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Plastic bronchitis is a rare life‐threatening complication of Fontan operation. When medical treatment is ineffective in the setting of high systemic venous pressures, Fontan fenestration may be considered to decompress venous pressures and improve cardiac output by creation of the right‐to‐left shunting. However, transcatheter approach can be difficult in patients with complex venous anatomy. We report a 4‐year‐old girl born with hypoplastic left ventricle and heterotaxy syndrome, who developed plastic bronchitis following extracardiac Fontan procedure. Her venous anatomy was complex with dextrocardia and interrupted inferior vena cava with azygos continuation. Stent fenestration was successfully performed via transhepatic approach, which was selected based on the anatomical relationship (between extracardiac conduit, left atrium, and hepatic veins) delineated by pre‐catheterization cardiac MRI. Simultaneous transesophageal echocardiography guided the intervention. Her plastic bronchitis improved significantly in 3 months but slowly progressed after the stent fenestration. At her 8‐month follow‐up, stent fenestration remains open and she is currently under heart transplantation evaluation due to persistent plastic bronchitis. Treatment of plastic bronchitis can be undertaken with Fontan fenestration, with pre‐procedural MRI playing an essential role in patients with complex venous anatomy. © 2012 Wiley Periodicals, Inc.</p> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 81:Issue 5(2013:Apr. 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 81:Issue 5(2013:Apr. 01)
- Issue Display:
- Volume 81, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 81
- Issue:
- 5
- Issue Sort Value:
- 2013-0081-0005-0000
- Page Start:
- 843
- Page End:
- 848
- Publication Date:
- 2012-08-07
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.24551 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4350.xml