Early percutaneous valve failure within bioprosthetic tricuspid tissue valve replacements. Issue 3 (14th March 2013)
- Record Type:
- Journal Article
- Title:
- Early percutaneous valve failure within bioprosthetic tricuspid tissue valve replacements. Issue 3 (14th March 2013)
- Main Title:
- Early percutaneous valve failure within bioprosthetic tricuspid tissue valve replacements
- Authors:
- Bentham, James
Qureshi, Shakeel
Eicken, Andreas
Gibbs, John
Ballard, George
Thomson, John - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd24622-sec-0001" sec-type="section"> <title>Objective</title> <p>To describe the cases of percutaneous valve failure following implantation of the Medtronic Melody™ and the Edwards Sapien™ valve in the tricuspid position. Background: There have been recent reports of the use of percutaneously delivered valves to manage failing bioprosthetic tricuspid valves. Total patient numbers remain small and follow‐up times are limited.</p> </sec> <sec id="ccd24622-sec-0002" sec-type="section"> <title>Methods</title> <p>We describe four procedures in three patients from two centers where implantation of percutaneous valves within the scaffold of a bioprosthetic tricuspid valve was technically successful but there was early valve failure.</p> </sec> <sec id="ccd24622-sec-0003" sec-type="section"> <title>Results</title> <p>In all cases, immediate results suggested excellent valve function; however, valve failure occurred early in three and later in one. Two patients elected for valve explantation and surgical placement of a further tricuspid valve. The third patient underwent a second percutaneous valve‐in‐valve procedure though this valve is also showing early signs of failure.</p> </sec> <sec id="ccd24622-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Transcatheter placement of percutaneous valves in the tricuspid position is technically a relatively straightforward procedure<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd24622-sec-0001" sec-type="section"> <title>Objective</title> <p>To describe the cases of percutaneous valve failure following implantation of the Medtronic Melody™ and the Edwards Sapien™ valve in the tricuspid position. Background: There have been recent reports of the use of percutaneously delivered valves to manage failing bioprosthetic tricuspid valves. Total patient numbers remain small and follow‐up times are limited.</p> </sec> <sec id="ccd24622-sec-0002" sec-type="section"> <title>Methods</title> <p>We describe four procedures in three patients from two centers where implantation of percutaneous valves within the scaffold of a bioprosthetic tricuspid valve was technically successful but there was early valve failure.</p> </sec> <sec id="ccd24622-sec-0003" sec-type="section"> <title>Results</title> <p>In all cases, immediate results suggested excellent valve function; however, valve failure occurred early in three and later in one. Two patients elected for valve explantation and surgical placement of a further tricuspid valve. The third patient underwent a second percutaneous valve‐in‐valve procedure though this valve is also showing early signs of failure.</p> </sec> <sec id="ccd24622-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Transcatheter placement of percutaneous valves in the tricuspid position is technically a relatively straightforward procedure but early valve failure raises some concerns about the viability of the valve in this position, at least in some patients. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 82:Issue 3(2013:Sep. 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 82:Issue 3(2013:Sep. 01)
- Issue Display:
- Volume 82, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 82
- Issue:
- 3
- Issue Sort Value:
- 2013-0082-0003-0000
- Page Start:
- 428
- Page End:
- 435
- Publication Date:
- 2013-03-14
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.24622 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3185.xml