Embozene™ microspheres induced nonreperfused myocardial infarction in an experimental swine model. Issue 4 (4th May 2012)
- Record Type:
- Journal Article
- Title:
- Embozene™ microspheres induced nonreperfused myocardial infarction in an experimental swine model. Issue 4 (4th May 2012)
- Main Title:
- Embozene™ microspheres induced nonreperfused myocardial infarction in an experimental swine model
- Authors:
- Varga‐Szemes, Akos
Kiss, Pal
Brott, Brigitta C.
Wang, Dezhi
Simor, Tamas
Elgavish, Gabriel A. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd24418-sec-0001" sec-type="section"> <title>Objectives</title> <p>To develop a magnetic resonance imaging (MRI) compatible, percutaneous technique for the generation of nonreperfused myocardial infarct (MI).</p> </sec> <sec id="ccd24418-sec-0002" sec-type="section"> <title>Background</title> <p>Modeling nontreated MI has major importance in the development and preclinical testing of new therapeutic strategies for patients missing the time window suitable for revascularization following MI.</p> </sec> <sec id="ccd24418-sec-0003" sec-type="section"> <title>Methods</title> <p>In 31 male swine, nonreperfused MI was generated by permanent occlusion of either the LAD or LCX coronary artery using 900 μm Embozene™ microspheres. Animals were monitored for 90 min postocclusion. Surviving animals were followed up for 2 (<italic>n</italic> = 6), 4 (<italic>n</italic> = 6), 14 (<italic>n</italic> = 6), or 56 (<italic>n</italic> = 6) days. At the end of the planned study session, contrast enhanced MRI, triphenyl‐tetrazolium‐chloride staining, and microscopic histopathology were carried out.</p> </sec> <sec id="ccd24418-sec-0004" sec-type="section"> <title>Results</title> <p>The mortality rate in this study was 22.6%. Intraoperative arrhythmias occurred in 14 cases: premature ventricular complexes with (5) or without (3) ventricular tachycardia, 2nd degree atrio‐ventricular block (1), and<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd24418-sec-0001" sec-type="section"> <title>Objectives</title> <p>To develop a magnetic resonance imaging (MRI) compatible, percutaneous technique for the generation of nonreperfused myocardial infarct (MI).</p> </sec> <sec id="ccd24418-sec-0002" sec-type="section"> <title>Background</title> <p>Modeling nontreated MI has major importance in the development and preclinical testing of new therapeutic strategies for patients missing the time window suitable for revascularization following MI.</p> </sec> <sec id="ccd24418-sec-0003" sec-type="section"> <title>Methods</title> <p>In 31 male swine, nonreperfused MI was generated by permanent occlusion of either the LAD or LCX coronary artery using 900 μm Embozene™ microspheres. Animals were monitored for 90 min postocclusion. Surviving animals were followed up for 2 (<italic>n</italic> = 6), 4 (<italic>n</italic> = 6), 14 (<italic>n</italic> = 6), or 56 (<italic>n</italic> = 6) days. At the end of the planned study session, contrast enhanced MRI, triphenyl‐tetrazolium‐chloride staining, and microscopic histopathology were carried out.</p> </sec> <sec id="ccd24418-sec-0004" sec-type="section"> <title>Results</title> <p>The mortality rate in this study was 22.6%. Intraoperative arrhythmias occurred in 14 cases: premature ventricular complexes with (5) or without (3) ventricular tachycardia, 2nd degree atrio‐ventricular block (1), and ventricular fibrillation (6). MRI, TTC, and histology confirmed the existence of MI in every case. Macroscopic pathology showed that the microspheres caused a practically total occlusion at the epicardial level of the coronary artery. Multiple infarcts were detected in one case, probably due to unintentional reflux of the microspheres. Microspheres retained in the coronary arteries did not cause any MRI artifact.</p> </sec> <sec id="ccd24418-sec-0005" sec-type="section"> <title>Conclusions</title> <p>The generation of nonreperfused MI is feasible by percutaneous injection of Embozene into the coronary artery system. The MI model thus obtained is suitable for the purposes of MRI experiments. © 2012 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 81:Issue 4(2013:Mar. 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 81:Issue 4(2013:Mar. 01)
- Issue Display:
- Volume 81, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 81
- Issue:
- 4
- Issue Sort Value:
- 2013-0081-0004-0000
- Page Start:
- 689
- Page End:
- 697
- Publication Date:
- 2012-05-04
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.24418 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3986.xml