Assessment of coronary stent deployment using computer enhanced x‐ray images‐validation against intravascular ultrasound and best practice recommendations. Issue 3 (19th January 2012)
- Record Type:
- Journal Article
- Title:
- Assessment of coronary stent deployment using computer enhanced x‐ray images‐validation against intravascular ultrasound and best practice recommendations. Issue 3 (19th January 2012)
- Main Title:
- Assessment of coronary stent deployment using computer enhanced x‐ray images‐validation against intravascular ultrasound and best practice recommendations
- Authors:
- Davies, Andrew G.
Conway, Dwayne
Reid, Scott
Cowen, Arnold R.
Sivananthan, Mohan - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p> <underline>Objective</underline>: To investigate the accuracy of stent measurements using coronary x‐ray angiograms with a computer based stent enhancement algorithm applied (StentBoost, SB). To derive recommendations for best practice when using such systems. <underline>Background</underline>: Computer enhancement algorithms allow better visualization of intracoronary stents to assist in ensuring adequate stent deployment. Factors that affect the accuracy of measurements taken on such systems are yet to be fully understood. <underline>Methods</underline>: We analysed stent deployment of 43 stents in 33 patients measuring minimum stent diameter and cross sectional area (CSA) using intravascular ultrasound (IVUS), SB enhanced x‐ray images, and quantitative coronary angiography (QCA). We investigated if the use of two projections and method of calibration influenced correlation between IVUS and SB measurements. <underline>Results</underline>: Using two views and performing calibration via the guide catheter improved agreement between SB and IVUS measurements. For example, minimum stent diameter assessed with SB using one view and balloon markers for calibration produced a correlation coefficient, <italic>r</italic>, of 0.21, whereas using two views and the guide catheter for calibration increased agreement to <italic>r</italic> = 0.62. Relative measures of stent deployment, such as the<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p> <underline>Objective</underline>: To investigate the accuracy of stent measurements using coronary x‐ray angiograms with a computer based stent enhancement algorithm applied (StentBoost, SB). To derive recommendations for best practice when using such systems. <underline>Background</underline>: Computer enhancement algorithms allow better visualization of intracoronary stents to assist in ensuring adequate stent deployment. Factors that affect the accuracy of measurements taken on such systems are yet to be fully understood. <underline>Methods</underline>: We analysed stent deployment of 43 stents in 33 patients measuring minimum stent diameter and cross sectional area (CSA) using intravascular ultrasound (IVUS), SB enhanced x‐ray images, and quantitative coronary angiography (QCA). We investigated if the use of two projections and method of calibration influenced correlation between IVUS and SB measurements. <underline>Results</underline>: Using two views and performing calibration via the guide catheter improved agreement between SB and IVUS measurements. For example, minimum stent diameter assessed with SB using one view and balloon markers for calibration produced a correlation coefficient, <italic>r</italic>, of 0.21, whereas using two views and the guide catheter for calibration increased agreement to <italic>r</italic> = 0.62. Relative measures of stent deployment, such as the ratio of minimum to maximum CSA, produced good correlation between IVUS and SB (<italic>r</italic> = 0.74). <underline>Conclusions</underline>: When using the SB system, two projection angles should be used to image the stent. For absolute measurements, the guide catheter should be used for calibration purposes. Relative measures of stent size, which are probably sufficient for assessment of deployment, also give good agreement with similar measures on IVUS, and require no calibration. © 2012 Wiley Periodicals, Inc.</p> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 81:Issue 3(2013:Feb. 15)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 81:Issue 3(2013:Feb. 15)
- Issue Display:
- Volume 81, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 81
- Issue:
- 3
- Issue Sort Value:
- 2013-0081-0003-0000
- Page Start:
- 419
- Page End:
- 427
- Publication Date:
- 2012-01-19
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.23366 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3833.xml