Uniform spinning sampling gradient electron paramagnetic resonance imaging. Issue 2 (8th March 2013)
- Record Type:
- Journal Article
- Title:
- Uniform spinning sampling gradient electron paramagnetic resonance imaging. Issue 2 (8th March 2013)
- Main Title:
- Uniform spinning sampling gradient electron paramagnetic resonance imaging
- Authors:
- Johnson, David H.
Ahmad, Rizwan
Liu, Yangping
Chen, Zhiyu
Samouilov, Alexandre
Zweier, Jay L. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm24712-sec-0001" sec-type="section"> <title>Purpose</title> <p>To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition.</p> </sec> <sec id="mrm24712-sec-0002" sec-type="section"> <title>Theory and Methods</title> <p>A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) and compared to the existing (equilinear spinning sampling, ESS) acquisition strategy. Novel corrections were introduced to reduce artifacts in experimental data.</p> </sec> <sec id="mrm24712-sec-0003" sec-type="section"> <title>Results</title> <p>Simulations demonstrated that USS puts an equal number of projections near each axis whereas ESS puts excessive projections at one axis, wasting acquisition time. Artifact corrections added to the magnetic gradient waveforms reduced noise and correlation between projections. USS images had higher SNR (85.9 ± 0.8 vs. 56.2 ± 0.8) and lower mean‐squared error than ESS images. The quality of the USS images did not vary with the magnetic gradient orientation, in contrast to ESS images. The quality of rat heart images was improved using USS compared to that with ESS or traditional fast‐scan acquisitions.</p> </sec> <sec id="mrm24712-sec-0004" sec-type="section"> <title>Conclusion</title> <p>A novel<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm24712-sec-0001" sec-type="section"> <title>Purpose</title> <p>To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition.</p> </sec> <sec id="mrm24712-sec-0002" sec-type="section"> <title>Theory and Methods</title> <p>A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) and compared to the existing (equilinear spinning sampling, ESS) acquisition strategy. Novel corrections were introduced to reduce artifacts in experimental data.</p> </sec> <sec id="mrm24712-sec-0003" sec-type="section"> <title>Results</title> <p>Simulations demonstrated that USS puts an equal number of projections near each axis whereas ESS puts excessive projections at one axis, wasting acquisition time. Artifact corrections added to the magnetic gradient waveforms reduced noise and correlation between projections. USS images had higher SNR (85.9 ± 0.8 vs. 56.2 ± 0.8) and lower mean‐squared error than ESS images. The quality of the USS images did not vary with the magnetic gradient orientation, in contrast to ESS images. The quality of rat heart images was improved using USS compared to that with ESS or traditional fast‐scan acquisitions.</p> </sec> <sec id="mrm24712-sec-0004" sec-type="section"> <title>Conclusion</title> <p>A novel EPRI acquisition which combines spinning gradient acquisition with a uniform sampling distribution was developed. This USS spinning gradient acquisition offers superior SNR and reduced artifacts compared to prior methods enabling potential improvements in speed and quality of EPR imaging in biological applications. Magn Reson Med 71:893–900, 2014. © 2013 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 71:Issue 2(2014:Feb.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 71:Issue 2(2014:Feb.)
- Issue Display:
- Volume 71, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 71
- Issue:
- 2
- Issue Sort Value:
- 2014-0071-0002-0000
- Page Start:
- 893
- Page End:
- 900
- Publication Date:
- 2013-03-08
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.24712 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3637.xml