Sensitive determination of the potential biomarker sarcosine for prostate cancer by LC–MS with N, N′‐dicyclohexylcarbodiimide derivatization. Issue 1 (2nd December 2013)
- Record Type:
- Journal Article
- Title:
- Sensitive determination of the potential biomarker sarcosine for prostate cancer by LC–MS with N, N′‐dicyclohexylcarbodiimide derivatization. Issue 1 (2nd December 2013)
- Main Title:
- Sensitive determination of the potential biomarker sarcosine for prostate cancer by LC–MS with N, N′‐dicyclohexylcarbodiimide derivatization
- Authors:
- Chen, Jing
Zhang, Juan
Zhang, Wenpeng
Chen, Zilin - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Sarcosine, a potential biomarker of prostate cancer, has drawn great attention in recent years. However, controversial research keeps arising about its role as a biomarker that might come from the two isomers (α‐alanine and β‐alanine) of sarcosine due to their same molecular weight and similar properties, which could interfere with the accurate detection of sarcosine. In this study, a simple and sensitive method was developed for the detection of sarcosine and the two isomers by LC with ion‐trap MS through a novel derivatization reagent <italic>N</italic>, <italic>N</italic>′‐dicyclohexylcarbodiimide. <italic>N</italic>, <italic>N</italic>′‐Dicyclohexylcarbodiimide is usually considered as a condensation reagent, however, it was directly used as a derivatization reagent through a rearrangement side reaction in this study. The proposed method not only improved the chromatographic retention behavior of sarcosine and its two isomers, which was a benefit to their separation, but also dramatically enhanced the detection sensitivity of sarcosine, which was more favorable for real sample analysis. The factors affecting the productivity of the derivatization reaction, such as reaction time and amount of derivatization reagent, were systematically optimized. The method shows good linearity (<italic>R</italic><sup>2</sup> &gt; 0.99), sensitivity with LODs of sarcosine as low as 1 ng/mL, and<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Sarcosine, a potential biomarker of prostate cancer, has drawn great attention in recent years. However, controversial research keeps arising about its role as a biomarker that might come from the two isomers (α‐alanine and β‐alanine) of sarcosine due to their same molecular weight and similar properties, which could interfere with the accurate detection of sarcosine. In this study, a simple and sensitive method was developed for the detection of sarcosine and the two isomers by LC with ion‐trap MS through a novel derivatization reagent <italic>N</italic>, <italic>N</italic>′‐dicyclohexylcarbodiimide. <italic>N</italic>, <italic>N</italic>′‐Dicyclohexylcarbodiimide is usually considered as a condensation reagent, however, it was directly used as a derivatization reagent through a rearrangement side reaction in this study. The proposed method not only improved the chromatographic retention behavior of sarcosine and its two isomers, which was a benefit to their separation, but also dramatically enhanced the detection sensitivity of sarcosine, which was more favorable for real sample analysis. The factors affecting the productivity of the derivatization reaction, such as reaction time and amount of derivatization reagent, were systematically optimized. The method shows good linearity (<italic>R</italic><sup>2</sup> &gt; 0.99), sensitivity with LODs of sarcosine as low as 1 ng/mL, and repeatability with the RSD &lt; 6.07%. The developed method was applied to the analysis of urine.</p> </abstract> … (more)
- Is Part Of:
- Journal of separation science. Volume 37:Issue 1/2(2014)
- Journal:
- Journal of separation science
- Issue:
- Volume 37:Issue 1/2(2014)
- Issue Display:
- Volume 37, Issue 1/2 (2014)
- Year:
- 2014
- Volume:
- 37
- Issue:
- 1/2
- Issue Sort Value:
- 2014-0037-NaN-0000
- Page Start:
- 14
- Page End:
- 19
- Publication Date:
- 2013-12-02
- Subjects:
- Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201301043 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3057.xml