Musculoskeletal Ultrasound Objective Structured Clinical Examination: An Assessment of the Test1. Issue 1 (January 2014)
- Record Type:
- Journal Article
- Title:
- Musculoskeletal Ultrasound Objective Structured Clinical Examination: An Assessment of the Test1. Issue 1 (January 2014)
- Main Title:
- Musculoskeletal Ultrasound Objective Structured Clinical Examination: An Assessment of the Test1
- Authors:
- Kissin, Eugene Y.
Grayson, Peter C.
Cannella, Amy C.
DeMarco, Paul J.
Evangelisto, Amy
Goyal, Janak
al Haj, Rany
Higgs, Jay
Malone, Daniel G.
Nishio, Midori J.
Tabechian, Darren
Kaeley, Gurjit S. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="acr22105-sec-0001" sec-type="section"> <title>Objective</title> <p>To determine the reliability and validity of an objective structured clinical examination (OSCE) for musculoskeletal ultrasound (MSUS).</p> </sec> <sec id="acr22105-sec-0002" sec-type="section"> <title>Methods</title> <p>A 9‐station OSCE was administered to 35 rheumatology fellows trained in MSUS and to 3 expert faculty (controls). Participants were unaware of joint health (5 diseased/4 healthy). Faculty assessors (n = 9) graded image quality with predefined checklists and a 0–5 global rating, blinded to who performed the study. Interrater reliability, correlation between a written multiple choice question examination (MCQ) and OSCE performance, and comparison of fellow OSCE results with those of the faculty were measured to determine OSCE reliability, concurrent validity, and construct validity.</p> </sec> <sec id="acr22105-sec-0003" sec-type="section"> <title>Results</title> <p>Assessors' interrater reliability was good (intraclass correlation coefficient [ICC] 0.7). Score reliability was good in the normal wrist and ankle stations (ICC 0.7) and moderate in the abnormal wrist and ankle stations (ICC 0.4). MCQ grades significantly correlated with OSCE grades (r = 0.52, <italic>P</italic> &lt; 0.01). The fellows in the bottom quartile of the MCQ scored 3.07 on the OSCE, significantly worse than the top quartile<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="acr22105-sec-0001" sec-type="section"> <title>Objective</title> <p>To determine the reliability and validity of an objective structured clinical examination (OSCE) for musculoskeletal ultrasound (MSUS).</p> </sec> <sec id="acr22105-sec-0002" sec-type="section"> <title>Methods</title> <p>A 9‐station OSCE was administered to 35 rheumatology fellows trained in MSUS and to 3 expert faculty (controls). Participants were unaware of joint health (5 diseased/4 healthy). Faculty assessors (n = 9) graded image quality with predefined checklists and a 0–5 global rating, blinded to who performed the study. Interrater reliability, correlation between a written multiple choice question examination (MCQ) and OSCE performance, and comparison of fellow OSCE results with those of the faculty were measured to determine OSCE reliability, concurrent validity, and construct validity.</p> </sec> <sec id="acr22105-sec-0003" sec-type="section"> <title>Results</title> <p>Assessors' interrater reliability was good (intraclass correlation coefficient [ICC] 0.7). Score reliability was good in the normal wrist and ankle stations (ICC 0.7) and moderate in the abnormal wrist and ankle stations (ICC 0.4). MCQ grades significantly correlated with OSCE grades (r = 0.52, <italic>P</italic> &lt; 0.01). The fellows in the bottom quartile of the MCQ scored 3.07 on the OSCE, significantly worse than the top quartile fellows (3.32) and the faculty (3.29; <italic>P</italic> &lt; 0.01). Scores also significantly discriminated bottom quartile fellows from faculty in the normal wrist and ankle stations (3.38 versus 3.78; <italic>P</italic> &lt; 0.01), but not in the abnormal stations (3.37 versus 3.49; <italic>P</italic> = 0.08).</p> </sec> <sec id="acr22105-sec-0004" sec-type="section"> <title>Conclusion</title> <p>MSUS OSCE is a reliable and valid method for evaluation of MSUS skill. Normal joint assessment stations are more reliable than abnormal joint assessment stations and better discriminate poorly performing fellows from faculty. Therefore, MSUS OSCE with normal joints can be used for the assessment of MSUS skill competency.</p> </sec> </abstract> … (more)
- Is Part Of:
- Arthritis care & research. Volume 66:Issue 1(2014:Jan.)
- Journal:
- Arthritis care & research
- Issue:
- Volume 66:Issue 1(2014:Jan.)
- Issue Display:
- Volume 66, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 66
- Issue:
- 1
- Issue Sort Value:
- 2014-0066-0001-0000
- Page Start:
- 2
- Page End:
- 6
- Publication Date:
- 2014-01
- Subjects:
- Arthritis -- Periodicals
Rheumatism -- Periodicals
616.72 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2151-4658 ↗
http://www3.interscience.wiley.com/journal/123227259/grouphome/home.html ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acr.22105 ↗
- Languages:
- English
- ISSNs:
- 2151-464X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4073.xml